Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 47 of 775

Datapump: Include Port number as an argument to DPDirect process command line

Datapump main process is DPDirect. Two of the arguments are source and destination SQL Services to pump data from one SQL to the other. The most common syntax uses to be like: DPdirect -i 40 -S :MS:<SrcHistorical>\OASYSHDB -D <system>:...
Angel Mario Moreno Arcos over 1 year ago in Enterprise SCADA Server / Datapump 0

Higher Visibility for Datapump Issues

Request that there be a better way to tell when Datapump is not pumping.
John Bjartveit 12 months ago in Enterprise SCADA Server / Datapump 0

[Test & DOC] Ability to configure datapump to pull data from an untrusted domain

Big Picture User Experience Officially test and document the feature added to datapump in OASyS 7.6R4 to allow pulling from an untrusted, lower security zone. Detailed Description Customer wants to datapump data from an untrusted domain into a tru...
Tyson Burr over 2 years ago in Enterprise SCADA Server / Administration / Installation / Datapump / Documentation 0 Future consideration

Search in Catalogue

Motivation Request from Technip: As the number of Class Libraries (or fragments) stored in the catalogue is growing, finding a given Class Library becomes harder. Proposed solution Provide a quick search in catalogue, searching in Class Library @i...
Geoffrey Coad almost 4 years ago in Information Standards Manager 0

Collect doesn't collect current real-time value at top of hour

Customer Requirement Our customers require the ability to maintain complete Timeseries historical trends (collect samples), including timestamped samples polled after a PLC communication loss (outage could be for several hours/days). The customer ...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime 2 Waiting for information

Alternate timeseries hourly averaging algorithm

Enhancement request to either allow integrators to modify timeseries averaging algorithm or provide hooks to allow integrator to modify the operation. We implemented an alternative timeseries averaging algorithm on many installations. Prior to bin...
Guest almost 4 years ago in Enterprise SCADA Server / Historical / Realtime API/SDK 1

Support extensions in ISM with > 1024 characters

Can we add an item onto the backlog to support extensions in ISM with > 1024 characters. Since we are using ISM for recording certain configuration, an example situation is a JSON template which may easily be larger than this, which will make a...
Andy Davidson almost 4 years ago in Information Standards Manager 0

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we co...
Rob Kenny over 2 years ago in Enterprise SCADA Server / Datapump 0 Reviewing

Tag Labels

From Jon Tomkins. Following up on an old enhancement request from the Aussies on ISM. It may not be seen as high priority but wanted to flag a pain point for implementation – when we are attempting configuration management of compositions, as toda...
Andy Davidson almost 3 years ago in Information Standards Manager 0

Required Version label is confusing

From Jon Tonkins: If a version is set to something like 1.0.2.*, understand this actually means ‘use latest version’. This reads confusingly as it looks like it should only be 1.0.2.something but can then be 1.0.3, etc.
Andy Davidson almost 3 years ago in Information Standards Manager 0