Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Thermodynamics

(Organic) solid prediction

Indication of solid precipitation condition; butane, benzene, CO2, H2S and C5+
Guest about 7 years ago in Advisory Group Ideas / Process Design / Thermodynamics 0 Considered for roadmap

Incorporate an interaction parameter(Kij) based mixing rule for Liquid viscosity correlation

Viscosity of glycerol-water solution at 20C and 70wt% glycerol does not match literature values. Zhizhong (John) Ding at Shell reported this issue.
Guest almost 4 years ago in Advisory Group Ideas / Thermodynamics 0 Implemented

Improve Excel copy/paste for pseudocomponent inputs

3/23/2023: This is done, available in version 2024 When copy/pasting data from Excel to the pseudocomponent creation screen, the number of columns selected in Excel must exactly match the number of columns in the PRO/II pseudocomponent screen (42 ...
Guest about 4 years ago in Advisory Group Ideas / Thermodynamics 0 Implemented

Edit binary interaction data using grid input

Currently binary interaction data must be entered one item at a time. This is inconvenient when there are many parameters to enter. It would be better if a tabular/grid input was provided, where # columns = # components and # rows = # components.
Guest about 4 years ago in Advisory Group Ideas / Thermodynamics 0 Implemented

[APS] TDM Supplied formula for custom component should calculate Molecular Weight

There is no relation between the molecular formula and the molecular weight, i.e., one can assign any values to MW, no matter what molecular formula is given. This can lead of course, if no attention is paid, to mass balance problems when dealing ...
Stelios Papastratos about 4 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized

Crude Assay input in tabular format in ProII [requested by Kock-Glitsch]

In ProII, they would like to characterize completely crude assays using a single table organized per boiling point ranges, as attached. This is because such format is the same that technicians use in their reports on crude assay.
Guest over 4 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized

Add UNIFAC Structure for Sulfolane on behalf of Shanghai Yankuang

I knew we have Sulfolane databank for NRTL BIP, however for Aromatic Extraction, there're still BIPs missing for Sulfolane with many components. If we provide the UNIFAC structure and contribution of Sulfolane, then those BIPs can be estimated fro...
Stephen Zhang over 4 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized

Introduction of thermodynamic package Esso tabular in ProII

A client showed interested in the thermodynamic package Esso tabular for ProII simulator. Currently it is not available in ProII but it is included in other software from competitors (e.g. Hysys). The method is particularly useful for the simulati...
Guest over 4 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized

Reactions with electrolyte thermo

Currently reactions are not allowed in column with Electrolytes. User has to manualy configure them in PROII along with kinetics data and use EOS or other thermo
Cristina Peretti about 5 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized

Include UNIFAC structure for DIPPRL only components. [On behalf of Idemitsu]

Components that are registered only in DIPPRL library do not have UNIFAC Structure because the original DIPPRL database doesn't include UNIFAC structure data. DIPPRL only components also do not have binary interaction parameters. Fill UNIFAC funct...
Guest about 5 years ago in Advisory Group Ideas / Thermodynamics 0 Received & categorized