To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 104 of 832

Allow dynamic object creation at runtime

In any object based language at runtime I can create and destroy objects. This is especially helpful when dealing with any dynamic data. IE: Pulling a row of data from a database. It would be great if I didn't need to create multiple attributes of...
Andrew Drane 6 months ago in Application Server / Development 0

The OPC UA driver should be able to read Tags, Alarms and Events

The OPC UA driver should be able to read Tags, Alarms and Events from other Scadas (iFix, Cimplicity, WinCC, Etc)
Guest about 2 years ago in Device Integration 1

S7TCP driver does not talk to PLCSIM Advanced

Not sure why my previous submission was deleted, so I send again. S7TCP driver needs update to resolve the issue with the communication with Siemens PLCSIM Advanced simulator while other SCADA software can easily talk to it.
Guest over 2 years ago in Device Integration 1

PRP (Parallel Redundancy Protocol, IEC 62439-3) support build into the product

Many solutions, especially in the infrastructure world dual networks are standard. ASP relies on Microsoft to manage it via teaming. Teaming does not provide real PRP redundancy. Teaming is also not available on non-server Windows operating system...
Marcell Marjee about 1 year ago in Application Server / Configuration 0

Graphics Performance Index summary

My idea is to have a way to get all Graphics performance index for a project when it’s about to close. Instead of of the developers going to the button and check one by one. For commissioning purposes would be very useful to have that list of all ...
Guest about 1 year ago in Application Server / Diagnostics 1

Proper MQTT Support

Note that I am no MQTT expert, but theses are the things I have picked up. We need to embrace MQTT in a generic way from the Operations Control Portfolio. We need to be able to adapt to a variety of of topic name space structures and to many diffe...
Deon van Aardt over 1 year ago in Device Integration 1

TrendPen

Remove the limit where the Trendpen can only trend data in the past.
Marcell Marjee over 1 year ago in Application Server / Visualization 0

Sort or filter S7TCP Tag Import

When using the Import Tags tool from the I/O Devices activity menu it lists all the available variables from the source PLC. It's not possible to sort or filter the list.
Liron Hallak over 1 year ago in Device Integration 1

Disabling ShowHalo from check box

Ability to disable ShowHalo not only via scripting but also via settings (check box in project settings)
Luca Preziosa 8 months ago in Application Server / Configuration 0

MBTCP - add support for IEC1131 address format (%MW, %MX...)

The IEC1131 address format is already supported by Schneider OFS, but it would be useful to have it supported in MBTCP OI Server. It would make it easier migrating from other drivers to OI Server without changing addresses. Another advantage is al...
Florian Champalle over 1 year ago in Device Integration 0