To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 148 of 776

UserInfo update

The UserInfo function is missing type/mode to return the comment field. WO to use the rdb file does not work, the _users.rdb file also does not contain the Comment field either.
Inge Kronstad over 2 years ago in Plant SCADA / Other 0

Citect Message mode Yes and No

There is a Cicode command called "Message". It has mode to show as OK and Cancel. But suggest to give another mode as Yes or No too.
Guest over 2 years ago in Plant SCADA / Development Tools 0 Future Consideration

genie long name

I would like to see a long name added to genies that would be visible in the screens->Libraries tab in Studio. Be able to apply a filter to the genie name and long name fields in the Library screen
Guest over 2 years ago in Plant SCADA / Graphics / Visualization 1 Unlikely to implement

OPC A&E (and/or OPC UA A&C) to support Areas

We have alarms split into several Areas. When we connect using an OPC AE Client it only shows the correct custom properties for alarms with Area 0. Seems the integrated OPC A&E Server connects to the Alarm database with a user which only can v...
Guest over 3 years ago in Device Integration 1

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

OPC UA Client - Multi Dimensional Array Tag

Are there any plans to support the OPC UA data type Multi Dimensional Array Tag?
Peter Chung over 2 years ago in Plant SCADA / Drivers / Protocols 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0

Use TagInfoEx() to check whether an alarm exists

If you have an equipment type with an item and this creates a variable tag and an alarmtag you could use the TagInfoEx() function to check whether this item has an alarm defined. Let me give an example: Equipment:Motors.M1 Item:Run Variable Tag Na...
Guest over 2 years ago in Plant SCADA / Equipment 0

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest over 1 year ago in Device Integration 1