To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 99

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest 10 months ago in Plant SCADA / Drivers / Protocols 0

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest about 1 year ago in Plant SCADA / Development Tools 0

Add ability to lock guidelines in Graphics Builder (so they dont change when you accidentally click them)

The problem is: in the graphics builder the guidelines can be clicked or dragged using the mouse, and then they change! Whilst dragging is quite a conscious action, clicking something is easily done accidentally. You are not warned that you clicke...
Guest over 2 years ago in Plant SCADA / Graphics / Visualization 1 Unlikely to implement

AVEVA Plant SCADA OMI App for SP

OMI App would simplify re-engineering of Plant SCADA Pages or help contextualise in SP. We are trying to sell more SP across APS sites.
Guest about 1 month ago in Plant SCADA / Graphics / Visualization 0 Submitted

Process Analyst - Bar graph

It would be good to add also bar graph trends.
Guest about 1 year ago in Plant SCADA / Alarms 0 Future Consideration

Process Analyst connects to WW Historian

Process Analyst can connect to Citect Historian ,ref to picture. Then is should be possible to connect to Aveva Historian alias WW Historian.
Guest almost 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Equipment Editor order elements alphabetically in the treeview

Just sort the treeview alphabetically
Guest about 1 year ago in Plant SCADA / Development Tools 0

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest over 1 year ago in Plant SCADA / Equipment 1 Future Consideration

Faster compiler

The old compiler needs to utilize modern hardware better to decrease compile-time. Also applies to other tools who I suspect uses same/similar routines working with DBFs and such. Like page update and packing, etc.
Guest 11 months ago in Plant SCADA / Development Tools 0 Future Consideration

Citect Studio - Insert Row, Insert Rows

There is no option to insert a new row record. Such an option could be useful. This can be done by DBF addin excel.
Guest over 1 year ago in Plant SCADA / Development Tools 0