To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 14 of 791

Python scripting in system platform

it would be great adding Python scripting to system platform making it easy and flexible to leverage the power of python
Guest about 1 year ago in Application Server / Scripting 3 Planned

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg 11 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Industrial Graphic script editor should ask for saving on Exit after ESC key press

When writing some scripts in Industrial Graphic editor, if we press ESC key by mistake, it closes, no matter if there was a script modified or written without asking for saving or not. So instead using Script editor i always write script in Notepa...
Marcin Wozniczka 7 months ago in Application Server / Scripting 2

Get Custom Property Reference by script

Allow retrieving a reference from a custom property to reuse it in a graphic. Example: indicate to the user the attribute used in a display and be able to find it in Historian.
Hugues Alexis 10 months ago in Application Server / Scripting 0

Need a replacement for PrintScreen() function that works in OMI

OMI is missing a way to programmatically print to printer. Like the PrintScreen function in InTouch. Should be able to print the whole application or only part of it, i.e. a popup window.Ref: IMS#2206203
Øyvind Hansen 4 months ago in Application Server / Scripting 1

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap