To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 41 of 776

OPC A&E (and/or OPC UA A&C) to support Areas

We have alarms split into several Areas. When we connect using an OPC AE Client it only shows the correct custom properties for alarms with Area 0. Seems the integrated OPC A&E Server connects to the Alarm database with a user which only can v...
Guest over 3 years ago in Device Integration 1

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest over 1 year ago in Device Integration 1

Leverage eDNA Historian as a Trend Data Storage Method in Citect

The eDNA History service is a high performance, lightweight historian. This Historian database would be a great replacement for the older flat file storage mechanism used by Citect. The eDNA historian would provide lossless, highly compressed stor...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

Cluster field when adding a pen to the process analyst should be a pull-down menu

When adding a pen to the process analyst, it would be great if the cluster field was a pull down with the available clusters listed from the project. With multi-cluster projects, this would help filter out the trend tag lists, as the end-user does...
Guest almost 6 years ago in Plant SCADA / Alarms 0 Future Consideration

Disable read from certain tags in knx driver

The driver will today read everything after a certain time if not otherwise refreshed. Some tags are not readable and event based only, to avoid uneccesary traffic there should be a possibility to disable read, similar to option for setpoints.
Dan Helgeland over 2 years ago in Device Integration 0

Process Analyst Static Background

The process analyst does not currently allow for the layering of static imagine behind a trend. A customer would like to have the ability to set a background, similar to how regular trends in Citect SCADA operate. I believe this is currently not i...
Guest about 5 years ago in Plant SCADA / Alarms 0 Future Consideration

DNP3 - "Listening mode"

The current version of DNPR or DNP3 driver always want's to initiate the start of communication with the device. There are some devices that work in an opposite direction (i.e. Metasphere DNP3 data loggers https://www.metasphere.co.uk/products/poi...
Ales B over 5 years ago in Device Integration 0