To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 28 of 791

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 2 years ago in Plant SCADA / Alarms 2 Future Consideration

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

Process Analyst - Bar graph

It would be good to add also bar graph trends.
Ales B over 2 years ago in Plant SCADA / Alarms 0 Future Consideration

Respect user input from printform when selecting landscapemode

I've a customer that needs to print trends with 5 different vertical scales and therefore use the old TrendDsp functions. (Process analyst only supports 2 vertical scales). The Customer want to print these trends and selects a printer, color mode ...
Guest about 4 years ago in Plant SCADA / Alarms 0

Native Hardware and Process Historical Alarm logging in SQL database

As current scenario, we can't log historical alarm into SQL database natively. Using alarm category we can log but is has it own limitation. Native functionality like Alarm Upload of CitectHistorian can be real upgrade for CitectSCADA as industry ...
Guest almost 6 years ago in Plant SCADA / Alarms 1 Future Consideration

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest about 4 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Ales B over 2 years ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung over 2 years ago in Plant SCADA / Drivers / Protocols 1 Future Consideration