To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 22 of 791

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest about 4 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Ales B over 2 years ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement

Add {equipment.ItemName} to reference objects in Equipment Editor

When working with a PLC that uses name based tags, such as Rockwell Control Logix 5000 series, creating equipment results in repetitive typing or copy and pasting which is not only time consuming, but adds possible user error when entering tags. F...
Guest about 4 years ago in Plant SCADA / Development Tools / Equipment 1

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung over 2 years ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

The SA include treeview control does not have the ability to change the order of the elements in a leaf.

It would be useful to change the order so that the tree can reflect the logical order of the process plant however that looks, for example the flow of material or process vs ancillary equipment or whatever rather than just alphabetically.
Guest over 1 year ago in Plant SCADA / Equipment 0

Add support basic math operations on Equipment Editor

I have an equipment with "x" tags with fixed offset. In address field i try to use:equipment.tagA Address property "={equipment.HC900_Addressing[BaseAddress]} + {equipment.HC900_Addressing[Offset]}". equipment.tagB Address property "={equipment.HC...
Guest 9 months ago in Plant SCADA / Equipment 0

Add global equipment filter to the Plant SCADA Studio which applies to all tables

If you want to see the variable tags, trend tags, alarm or configuration parameters of one piece of equipment you have to apply an equipment filter for every type. If you could select an equipment filter in the top right of the Plant SCADA Studio ...
Guest 11 months ago in Plant SCADA / Equipment 0

The SA Treeview needs an option to hide the cluster node

One major use of clustering is for distributed processing on large sites. In this case it makes no sense for the cluster name to be part of the equipment tree as it may be arbitrarily assigned and named.
Guest about 1 year ago in Plant SCADA / Equipment 0 Submitted