To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest almost 2 years ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 6 years ago in Device Integration 2

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle about 2 years ago in Device Integration 0 Planned

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest about 3 years ago in Plant SCADA / Drivers / Protocols 1 Reviewed & Categorized

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest almost 2 years ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest about 2 years ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

SNMP-driver to support V3

From cybersecurity perspective end-users now have requirements to use V3, but this is currently not supported.
Guest 10 months ago in Device Integration 2

Possibility to modify values directly in the SIM OI-Server

For testeing purposes, the OI-Server SIM can be handy. The only missing thing here is the possibility to modify values directly through the UI of it. I now use the WWClient to do this to get the values I want in my Galaxy environment. A added valu...
Lauran Lint over 1 year ago in Device Integration 0

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest almost 5 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Ales B about 3 years ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement