To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 42 of 776

Deployment Server initialize connection to clients to comply with NIS-Directive

With the NIS-Directive in place it would help to have the deployment server initializing the connection to all clients as it is quite common to have deployment server in a "secure" zone and the clients in a "unsafe" DMZ, so we don't want to open a...
Guest almost 2 years ago in Plant SCADA / Development Tools 0

VSCode / Cicode Editor

Provide a language (Cicode) template / library that can be imported into VSCode. This would allow for some additional features that are sorely lacking in the Cicode editor. For example linting tools.
Guest about 4 years ago in Plant SCADA / Development Tools 2

Add {equipment.ItemName} to reference objects in Equipment Editor

When working with a PLC that uses name based tags, such as Rockwell Control Logix 5000 series, creating equipment results in repetitive typing or copy and pasting which is not only time consuming, but adds possible user error when entering tags. F...
Guest about 4 years ago in Plant SCADA / Development Tools / Equipment 1

User Defined Types - instances with overrides

The UI for user defined types in InTouch is almost there. When selecting an instance, we'd like to use that UI to override things like item or EU units for example. Doing so via JSON is not going to work for most customers.
Andrew Flournoy over 1 year ago in InTouch HMI 1 Planned

Add the item name as a column in the tagname dictionary.

This would stop people from making duplicate tags when they can't locate an item name that already exists, and make troubleshooting way easier when vendors use different tagnames than the PLC item name.
Guest 8 months ago in InTouch HMI 1 Will not implement

Find user function from Plant SCADA Studio

Add an extra search option in the Find & Replace option in the Studio. The Project Editor used to have this option.
Guest about 3 years ago in Plant SCADA / Development Tools 2

Modify the language DBFs from the Plant SCADA Studio

Instead of using Excel (or any other DBF editor) use the Plant SCADA Studio to modify the english.dbf, dutch.dbf of any other language . There is already a Setup -> Languages grid
Guest almost 3 years ago in Plant SCADA / Development Tools 0

Stop modifying Industrial Graphics when opening WindowMaker

Every time WindowMaker is opened, all Industrial Graphics get touched with a new date/time. This results in NAD or manual sync operations sending all the graphics each time despite nothing actually having changed.
Andrew Flournoy about 1 year ago in InTouch HMI 0

Make Alarm Hotbackup Manager fully integrated into InTouch

The utility named Alarm Hotbackup Manager isn't a service nor needs to stay running. It simply makes an INI that is utilitized by InTouch runtime. Then alarms are sycned via an inocuous alarm grid with a query calling for said named pair. Why isn'...
Andrew Flournoy over 1 year ago in InTouch HMI 1

Modify real time values in runtime cicode debug

In Cicode editor, debug mode, it would be useful if we can change a variable value or return value from function (maybe with context menu in stack window and globals window). We have TagDebug for tags, but for cicode variables it's not possible, s...
Guest over 5 years ago in Plant SCADA / Development Tools 0 Future Consideration