To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Retentive values for UDT

Hi, UDT are missing retentive value option. Would it be possible to add it to prevent customer using legacy tags for a such feature ? Thanks
Mathieu VANTARD 9 months ago in InTouch HMI 0 Planned

Propagating InTouch tags renaming to ArchestrA Graphics

For now, if you rename an InTouch tag, it's also renamed in all windows, scripts, animation .... but not in ArchestrA Graphic.
Guest 10 months ago in InTouch HMI 0

Expose scripts in Industrial Graphics

When printing an application, this allows us to understand all scripts in InTouch. Anything within Industrial Graphics isn't included. There should be a mechanism to show all scripts in the graphics for troubleshooting and optimization.
Andrew Flournoy about 2 years ago in InTouch HMI 1

Improve language selection during the installation of InTouch HMI.

When a new InTouch HMI installation is performed, a language selection dialog box appears and English is always selected by default. However, according to the documentation, language versions of InTouch are only supported for the language of the c...
Fabrice Leonard about 1 year ago in InTouch HMI 0

Add setting for application resolution

Currently there is no easy way to change the resolution of an application. Many of us are now working on development services and remote boxes where we don't have the option to change display resolution. The old method of "Change your resolution, ...
Andrew Drane about 1 year ago in InTouch HMI 1 Planned

History Log Viewer Update

The History Log Viewer to view LGh files does not function anymore with the new 2023 LGH files. This was useful to determine if the Trends were not working properly or if the LGH files are corrupted. THe History Log Viewer should be updated to inc...
Guest about 1 year ago in InTouch HMI 1 Planned

Ability to print in Landscape using PrintScreen Function

Our client, an SI on behalf of their end user reached out requesting this feature. When asked to elaborate on the need, the impact of not having this feature and the desired end goal, the client provided the following explanation: " The need is dr...
Mari Camejo about 1 year ago in InTouch HMI 0

Undo for redefined values for UDT data type

We can redefine/override values on some level of UDT template structure (MinEU, MaxEU, Alarm Group etc.) But once it is done, there is no way to undo it, and ensure that the UDT type inherits the value again from its ancestor data type (as if it w...
Pavel Prusa about 1 year ago in InTouch HMI 0 Planned

When multiple language settings are configured, you can designate a specific language as the default language, and launch the application in development with the default language while displaying the non-default languages.

At present, it can be seen that InTouchView only uses the language selected during installation as the starting language when it starts up. In multi-language usage scenarios, a target language has to be selected each time, which is an unnecessary ...
Penghui Bi over 1 year ago in InTouch HMI 1

Datapump: Include Port number as an argument to DPDirect process command line

Datapump main process is DPDirect. Two of the arguments are source and destination SQL Services to pump data from one SQL to the other. The most common syntax uses to be like: DPdirect -i 40 -S :MS:<SrcHistorical>\OASYSHDB -D <system>:...
Angel Mario Moreno Arcos over 2 years ago in Enterprise SCADA Server / Datapump 0