Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Enterprise SCADA Server

AD LDS Cross-Domain Replication instructions

Cross domain AD-LDS replication can be configured in in 3 ways. Automtic - no user involvement Manual through XML export and import Manual through NMC optoin manue by sending the information and and on the receiving end clicking the "Recieve...
Vitali Unke 7 days ago in Enterprise SCADA Server 1 Planned

Enhancement to MTPAlarmManager Class

No description provided
Rob Kenny 2 months ago in Enterprise SCADA Server / Alarms 1 Waiting for information

Requesting testing of disabling WPAD and LMHASH

Security audits have found the following settings are enabled in the environment. Requesting testing for the following security recomendations. Disable HTTP proxy features: Disable WPAD https://www.tenable.com/audits/items/CIS_Microsoft_Windows_Se...
Andrew Potkins about 2 months ago in Enterprise SCADA Server 1 Reviewing

Logging Point Names Instead of PTNUMs

The request os to log names rather than ptnums in ModificationAudit wherever possible
Rob Kenny 2 months ago in Enterprise SCADA Server / ADE / PnT / MoC 1 Future consideration

Document the details of TimeSeries aggregated tables

Document how the value, maxValue, minValue and the corresponding time fields and the averageValue fields are generated for the TimeSeries hour, Day, Month and Year tables
Vitali Unke 3 months ago in Enterprise SCADA Server / Documentation 0

Productize script conversion from none summarized to summarized TimeSerise

For customers who want to convert from non-simirized timeserise to a summurized tiem series they need to execute a script to convert their data. This will enable them to use DTR on their Trends. DTR does not support non-summrized Data. The attache...
Vitali Unke 4 months ago in Enterprise SCADA Server 0 Future consideration

Custom alarm severities

No description provided
Vitali Unke 2 months ago in Enterprise SCADA Server 0 Planned

Modification Request to Alarm Suppression Functionality

When a Parent point goes stale, alarm suppression associated with that point is removed.
Rob Kenny 2 months ago in Enterprise SCADA Server / Alarms 1 Will not implement

Improve the warning/alarm message of the Admin Pager for low Physical Memory threshold

The default wmimonitor alarm message reports "freespace" is below warning\alarm limit for both low physical memory and logical disk. Requesting the messages are updated to be more clear which resource is affected by changing the physical memory me...
Vitali Unke 9 months ago in Enterprise SCADA Server / Alarms 0

Allow chained VDB field put overrides so integrators can override baseline fields

During development of some CIP functionality for [a customer], (EXT-417), we needed to trigger some protocol specific functionality when the "poll group" field changes. However, when we added a VDB override, it wasn't called. [R&D Architect] h...
Collin Heggerud over 2 years ago in Enterprise SCADA Server / Realtime API/SDK 1 Reviewing