Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 22 of 791

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

Add SwX Alarm page customisation features to SA_Include alarm page

SwX Alarm pages had some useful features that are not available in the Situational Awareness project, for example: Add/Remove columns at runtime Re-order columns at runtime Auto-fit columns It would be great to see these features in the standard S...
Guest about 4 years ago in Plant SCADA / Alarms / Graphics / Visualization 0

Right click on a alarm - Navigate

I have a customer who wishes that users with insufficient privileges are not allowed to "Navigate" to the alarm. So basically. The same behavior as acknowledging and shelving that is greyed out (See the attached picture). Or at least have an optio...
Peter Chung almost 2 years ago in Plant SCADA / Alarms 0

New alarm type (like Double point status alarm) which support 64 states

V2023R2 introduced the double point status alarm. This type of alarm can handle 8 different states. This very limited. Should be at least 32 states or preferrably 64.
Guest almost 2 years ago in Plant SCADA / Alarms 1 Unlikely to implement

Initialize the memory of a variable when switched On using Director command

In Connoisseur we had the capability to re-initialise a specific variable when switching it ON. That is, delete its previous variation history to clear out any inconsistent or untypical behaviour (eg startup). This functionality should be enabled ...
Jan Ledwon almost 3 years ago in APC / General 0 In development

Standard Deviation function for custom calculations

We often need to use SD in calculations. However it is not a standard function available under custom calculations. Please can we add it there.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Excel Data import improvements

New feature in 2022 SP1 works great already, but some suggestions for further development: allow import from multiple sheets of Excel workbook if tagname is missing for a particular column, substitute a default (currently the data gets mis-aligned...
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

Leverage eDNA Historian as a Trend Data Storage Method in Citect

The eDNA History service is a high performance, lightweight historian. This Historian database would be a great replacement for the older flat file storage mechanism used by Citect. The eDNA historian would provide lossless, highly compressed stor...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration