Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

[On behalf of Advisory Group] Update NRTL BIPs for Water-Hydrocarbons Systems

Cover desalter condition typically 300F. Current BIPs looks to cover just the ambient range.
Seiya Hirohama almost 3 years ago in Advisory Group Ideas / Process Design / Thermodynamics 0 Implemented

Redlich-Kister equation as mixing rule for different properties

Redlich-Kister can be used as mixing rule with adjustable binary interaction parameter (kij) for different properties, such as viscosity, density, heat capacity, surface tension, thermal conductivity, and others.The equation is flexible and it dea...
Guest 7 months ago in Advisory Group Ideas / Thermodynamics 0 Considered for roadmap

[Daikin] Addition of "Residence Time" option for PRO/II CSTR model reactor data specification

Currently, only "Reactor Volume" is available for CSTR reactor data specification. However, "Residence Time" is firstly considered when designing phase. It'd be more convenient if "Residence Time" option becomes availabe.
Naoko Harada about 3 years ago in Advisory Group Ideas / Process Design 0 Implemented

PRO/II: [ON behalf of Air Water] Enhancement Request for Conversion Reactor Reference Condition Setting

PRO/II conversion reactor has two options for enthalpy reference condition; Ideal Gas Enthalpy (default) and Reference Pressure. When Ideal Gas Enthalpy option is selected, enthalpy at reference condition is calculated by Ideal Gas Enthalpy method...
Naoko Harada about 1 year ago in Advisory Group Ideas / Process Design 0 Submitted

Ejector to allow any other Gas as Primary Motive Fluid instead of only "Steam" [PRO/II] European Customer

Ejector that could use any other gases and not being only steam (High Pressure Natural Gas, Nitrogen) Allow any gas stream available in flowsheet to be the Primary Motive Fluid User can specify today a custom Cp/Cv ratio.
Stelios Papastratos over 3 years ago in Advisory Group Ideas / Process Design 2 Submitted

Use of DEFINE directly in a stream [PRO/II] on behalf or European Customer via Vladimir Lyakutkin

We have today available workarounds (Calculator, Component Calculator, Controller). The objective here is to easily define flows as a function of other stream flows. Exitsing references ADO 243249 / LFCR#5144 SR# 109810631
Stelios Papastratos about 6 years ago in Advisory Group Ideas / Process Design 3 Not considered

[On behalf of TOPSOE] Transport Properties for single Pseudo-Component

In PRO/II, when the user defines a distillation curve (assay), the software automatically generates a set of Pseudo-Components (identified as BLND... in stream results). Currently some Component Properties are accessible for each individual pseudo...
Antonello Fiorillo 8 months ago in Advisory Group Ideas / Process Design 0 Submitted

Calculator Enhancement

The current dialog box for Calculator in PROII is small. in some cases we have a large number of parameters in a calculator, and it is inefficient and prone to errors when we have to navigate back/forth between “Parameters”/“Results” and scroll up...
Guest over 6 years ago in Advisory Group Ideas / Process Design 1 Implemented

Obtaining heat curves directly from the heat exchangers in AVEVA Process Simulation

In AVEVA PRO/II Simulation it's possible to evaluate the standard heat curve directly from the heat exchangers and the results are shown in the text report, so the ideia is to have this feature in AVEVA Process Simulation.
Guest over 1 year ago in Advisory Group Ideas / Process Design 0 Submitted

AVEVA Advisory Group Meeting November 2022 - Presentations

This is just a repository for all presentations shared during the AVEVA Advisory Group Meeting (Nov 22) in San Francisco. Vote for this idea to let us know that you have visited this link
John Hernandez almost 4 years ago in Advisory Group Ideas / Process Design 0 Implemented