To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 30 of 776

Define Controller Watchdog Tags

allow them to be selected from a List, avoid the potential for typos and other errors.
Geoff Lewis over 2 years ago in APC / Controller Configuration 0 Evaluating

Define DCS Readback and DCS Status

When defining these tags in a controller, allow them to be selected from a list of all Input Tags, with possibility to apply a filter to limit the size of the presented list. Currently we have to enter the text directly with all kinds of possibili...
Geoff Lewis over 2 years ago in APC / Controller Configuration 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Prediction Mode (Open Loop)

Provide a "prediction mode" for the controller where it can read the values from the DCS and predict the steady state values of the CVs but it cannot write back the setpoints to PID controller in DCS. Read-only connectivity to the DCS, moves are c...
Ina Llewellyn almost 3 years ago in APC / Connectivity 1 In development

Enumerated value tag type

Similar to a "discrete" with "message" strings, but with N integer states instead of just 0/1.
Elliott Middleton almost 2 years ago in Historian & Client / Data Acquisition 0 Submitted

Reliable data collection from InTouch

Support reliable data collection for applications with InTouch and Historian, such as with Redundant Tag Servers. This should parallel how Redundant Engines and Redundant DI Objects work with Historian in a System Platform solution. A lower priori...
Elliott Middleton about 4 years ago in Historian & Client / InTouch 0 Submitted

Indirect Tag for "SliceBy"

In our case (and I suspect others) we have many of the same type of equipment. It would be ideal to be able to specify a tag name pattern or something of that nature in the SliceBy call. This would avoid us having to iterate through a list of tags...
Elliott Middleton about 2 years ago in Historian & Client / Expressions 0 Submitted

HCAP Ping Utility

A command line utility to test HCAP/HCAL connectivity.
Elliott Middleton over 2 years ago in Historian & Client / Install and Upgrade / Maintenance and Management 0 Submitted

Filtering stats based on conditions

When comparing control performance with and without APC, it would be helpful to see separately the average, std,... when APC is on or off based on the value of the controller status tag. The same philosophy could be applied to get statistics only ...
Eduardo Sanchez over 2 years ago in APC / Trends 0 Evaluating

More complete information about store-forward operations sending to Insight

The customer has the following question regarding Aveva Insight. They use the Aveva Insight Publisher to publish the data from a vessel to the online Aveva Insight Historian using the store-and-forward functionality as the connection at sea is not...
Elliott Middleton over 2 years ago in Historian & Client / Store and Forward 1 Unlikely to implement