To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 92

InTouch: add configurable item name prefix for Access names

It would be very useful to be able to configure an item name prefix for each Access Name. This prefix would be added to the "item name" of each tag configured to use the given Access Name. If you want InTouch to communicate with Siemens S7-1200 or...
Florian Champalle about 1 year ago in InTouch HMI 1

Add setting for application resolution

Currently there is no easy way to change the resolution of an application. Many of us are now working on development services and remote boxes where we don't have the option to change display resolution. The old method of "Change your resolution, ...
Andrew Drane 3 months ago in InTouch HMI 1 Planned

History Log Viewer Update

The History Log Viewer to view LGh files does not function anymore with the new 2023 LGH files. This was useful to determine if the Trends were not working properly or if the LGH files are corrupted. THe History Log Viewer should be updated to inc...
Guest 3 months ago in InTouch HMI 1 Planned

enhance DBload to accommodate alarm inhibitors that exist in subsequent lines

when rebuilding an application (we all have to from time to time), the first step is dbdump / load. For mature applications, this commonly fails due to tags used as alarm inhibitors prior to actually being defined. Maybe the load can create all ta...
Guest 7 months ago in InTouch HMI 1

QuickFunctions in Industrial Graphics

The use of QuickFunctions Calls in Industrial Graphics Action Scripts
Steffen Vestergaard 8 months ago in InTouch HMI 1 Planned

Bring Back Toolbars

Toolbars were removed from InTouch HMI in SP2023. The current tabular user interface does not leave much room for the main event - seeing Windows and QF/Script Editor. Things like access to colors, text, font, drawing lines, adding text, bitmaps, ...
Guest 11 months ago in InTouch HMI 0

User Defined Types - instances with overrides

The UI for user defined types in InTouch is almost there. When selecting an instance, we'd like to use that UI to override things like item or EU units for example. Doing so via JSON is not going to work for most customers.
Andrew Flournoy over 1 year ago in InTouch HMI 1 Planned

Undo for redefined values for UDT data type

We can redefine/override values on some level of UDT template structure (MinEU, MaxEU, Alarm Group etc.) But once it is done, there is no way to undo it, and ensure that the UDT type inherits the value again from its ancestor data type (as if it w...
Pavel Prusa 5 months ago in InTouch HMI 0 Planned

When multiple language settings are configured, you can designate a specific language as the default language, and launch the application in development with the default language while displaying the non-default languages.

At present, it can be seen that InTouchView only uses the language selected during installation as the starting language when it starts up. In multi-language usage scenarios, a target language has to be selected each time, which is an unnecessary ...
Penghui Bi 5 months ago in InTouch HMI 1

Stop modifying Industrial Graphics when opening WindowMaker

Every time WindowMaker is opened, all Industrial Graphics get touched with a new date/time. This results in NAD or manual sync operations sending all the graphics each time despite nothing actually having changed.
Andrew Flournoy over 1 year ago in InTouch HMI 0