Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 615

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung almost 2 years ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Areas on special days, like the scheduler.

Today you can separate for example different customers in diffrent areas. When thet use Citect timeschedule they can only see their areas. But if they go to special days, they can see/delete/edit everything. The problem we have is that different c...
Guest almost 2 years ago in Plant SCADA / Other 0

SNMP AES v3

Hi Team, more and more customers are looking to integrate network devices or power devices in system platform via SNMP. But these devices utilize v3 AES most cyber secure encryption mentor. Our drivers only support DES at the moment leading the cu...
Lakshay Mundeja 4 months ago in Device Integration 2 Planned

Persist warning bar state on edit record form

The hide button for the yellow warning bar should be remembered by Production Analyst (see images attached). So that if the hide button is enabled, when editting following records, the hide button is still enable, vice versa.
Nina NICHOLLS 4 months ago in Production Management (AMPLA MES) / Client 0 Future consideration

Modern text input animation

Please update the text input animation by disabling the text input popup that appears on element when enabling userinput animation. This instaneoulsy destroy any U.I. / U.X. effort. Could be nice to include custom Regex rules -> avoid scripting...
Mathieu VANTARD 4 months ago in Application Server & OMI / Industrial Graphics 0

Citect S7TCP driver to be updated.

CITECT S7TCP driver is not able to communicate with Siemens PLCSIM Advanced V5.0 while other SCADA Software are able to do so.
Guest over 1 year ago in Device Integration 2

Find user function from Plant SCADA Studio

Add an extra search option in the Find & Replace option in the Studio. The Project Editor used to have this option.
Guest over 2 years ago in Plant SCADA / Development Tools 2

Citect Studio Login

Instead of an error message when trying to start studio as a user who is not a member of the "SCADA.ConfigUsers" local group. Why not present a login form, similar to Deployment Server? This would reduce frustration, and also many times users thin...
Guest 4 months ago in Plant SCADA / Development Tools 0 Future Consideration

flowTotalConfig integration blocks replication enhancement request

Our customer has a business need to be able to manually adjust previous hour/day/month etc of a flowTotal record. So that it provides accurate information in the control room so that GCN records can be met and gas used can be properly tracked.Ofte...
Vitali Unke 4 months ago in Enterprise SCADA Server 0

MBTCP - add support for IEC1131 address format (%MW, %MX...)

The IEC1131 address format is already supported by Schneider OFS, but it would be useful to have it supported in MBTCP OI Server. It would make it easier migrating from other drivers to OI Server without changing addresses. Another advantage is al...
Florian Champalle 4 months ago in Device Integration 0