Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 102

Process Analyst connects to WW Historian

Process Analyst can connect to Citect Historian ,ref to picture. Then is should be possible to connect to Aveva Historian alias WW Historian.
Guest about 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 1 year ago in Plant SCADA / Alarms 2 Future Consideration

Fontsize ciode form functions

The posibility to change the fontsize, font used in the cicode form functions.
Guest 9 months ago in Plant SCADA / Graphics / Visualization 0

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 0

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 1 year ago in Plant SCADA / Development Tools 0

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 2 years ago in Plant SCADA / Alarms 0 In Roadmap

Process Analyst - Bar graph

It would be good to add also bar graph trends.
Guest over 1 year ago in Plant SCADA / Alarms 0 Future Consideration

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest almost 2 years ago in Plant SCADA / Equipment 1 Future Consideration

Citect Studio - Insert Row, Insert Rows

There is no option to insert a new row record. Such an option could be useful. This can be done by DBF addin excel.
Guest almost 2 years ago in Plant SCADA / Development Tools 0

Equipment Editor order elements alphabetically in the treeview

Just sort the treeview alphabetically
Guest over 1 year ago in Plant SCADA / Development Tools 0