To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 697

Multi-object properties editing

Ability to modify multiple common properties across several templates at once (e.g., unit of measure, writability, I/O scaling, etc.)
Luca Preziosa 16 days ago in Application Server / Configuration 1

Disabling ShowHalo from check box

Ability to disable ShowHalo not only via scripting but also via settings (check box in project settings)
Luca Preziosa 16 days ago in Application Server / Configuration 0

Custom Namespaces values in Object Viewer

Enable the ability to view the runtime values of Custom and Standard Namespaces in the Object Viewer.
Luca Preziosa 16 days ago in Application Server / Diagnostics 0

Enhance flexibility in customizing Galaxy Styles (unlimited user defined styles and import of design tokens)

To enhance design flexibility, we would suggest the following : Enable users to create and manage unlimited custom styles. Allow to define Galaxy styles with raw values as well as variables (design tokens) Support variables import from external so...
Marie Gerno 8 months ago in Application Server / Visualization 0

Ability to Integrate IDE with standard source control tools (i.e. GIT, TFS, SVN)

With the discontinuation of Autosave 4 System Platform, the IDE is lacking any ability for doing source control. It would be great to have this as a native feature. Use Case 1 : Developers tracking code changes, DIFF, rolling back code, etc… Ideal...
Jim MacDonald 11 months ago in Application Server 1

Properly handling default values and locks in the IDE

Currently users use the lock functionality to set a default value for an attribute but this locks the value at instance level and at every template level in between the configured template and the instances. It means that users need to go back and...
Ernst Van Wyk 12 months ago in Application Server / IDE 3 Planned

Add auto formatting to object scripts

Formatting and auto indenting has been a staple in all programming languages regardless of IDE for decades. Please add this to the script editor within the objects. Will immensely help code readability. I should not have to cut all my script, past...
Andrew Drane 4 months ago in Application Server / IDE 0

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon about 3 years ago in Plant SCADA / Graphics / Visualization 1

Remove more than 1 version in the deployment server at a time

It would be highly beneficial to introduce the capability to remove multiple versions simultaneously. Additionally, an automated feature to retain only the latest 10 versions.
Peter Chung about 1 year ago in Plant SCADA / Other 0

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest 5 months ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement