To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 122 of 643

Long Term Servicing for PlantSCADA

Standard Term Servicing is provided by AVEVA for all Citect versions which includes 3 years of full support. After the 3 years the following support is dropped. Minor and Major version releases Patches to address non-critical issues Ability to req...
Guest 15 days ago in Plant SCADA / Other 2 In Roadmap

Pre-Release/Beta Version of Releases

When initiating new projects we often specify a Citect version to be used early on in the process knowing full well that major projects can take 6-Months to a year to go from concept to commissioning. If during the development AVEVA releases a new...
Guest 5 days ago in Plant SCADA / Development Tools 1

SQL outside Cicode or mechanism for inserting data into different database with specific period

When we want use 3rd party tool like Grafana , Node Red, Wordpress and many others we need data from different database. Need a mechanism for transferring data from trend files to the database like MSSQL. MongoDB, MariaDB, MySQL but without write ...
Guest 2 months ago in Plant SCADA / Historic Data / Storage 1 Submitted

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg 3 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest 4 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

Remove more than 1 version in the deployment server at a time

It would be highly beneficial to introduce the capability to remove multiple versions simultaneously. Additionally, an automated feature to retain only the latest 10 versions.
Peter Chung 11 months ago in Plant SCADA / Other 0

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest 4 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

Web content object to support URLs longer than 255 characters

I would like to request support for long URLs (over 255 characters) in the "new" Web Content control object. I imagine something similar to how it’s done with SQL using SqlSet and SqlAppend. The DspPopupMenu() function also supports working around...
Guest about 1 month ago in Plant SCADA / Graphics / Visualization 3 Unlikely to implement

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon almost 3 years ago in Plant SCADA / Graphics / Visualization 1

Add support basic math operations on Equipment Editor

I have an equipment with "x" tags with fixed offset. In address field i try to use:equipment.tagA Address property "={equipment.HC900_Addressing[BaseAddress]} + {equipment.HC900_Addressing[Offset]}". equipment.tagB Address property "={equipment.HC...
Guest 19 days ago in Plant SCADA / Equipment 0