Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 122 of 652

Deployment supporting Terminal Server and Profiles

Deployment is not officially and 100% supporting Terminal Server systems. Supporting this by the Deployment Server and also the possibility to select a Profile for the Terminal Server and not is needed.
Guest over 5 years ago in Plant SCADA / Development Tools 1 Future Consideration

Have a button to remove all filters on Plant SCADA Studio table and to indicate a filter is applied.

When using multiple filters on a table like variable tags in Plant SCADA Studio, it would be handy to be able to hit a clear filter button and it removes the filter from all fields. Sometimes a filter is applied to a column that isn't visible, thi...
Guest over 2 years ago in Plant SCADA / Other 0

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest about 5 years ago in Plant SCADA / Alarms 0 Future Consideration

Export Visualization - Libraries

One of our customer has several Plant SCADA Projects, all based on the same company library project. V2020R2 and up show the number of of instances of each template, genie and symbol. If the counter is 0 you could delete the library object, but it...
Guest over 2 years ago in Plant SCADA / Graphics / Visualization 0

A function to get the number of display clients connected to a server process

Existing ServerInfoEx() function gives the number of server side Trans of a specified service type but there is no way to get the number of display clients connected to a server.
Guest about 5 years ago in Plant SCADA / Other 0 Future Consideration

Add {equipment.ItemName} to reference objects in Equipment Editor

When working with a PLC that uses name based tags, such as Rockwell Control Logix 5000 series, creating equipment results in repetitive typing or copy and pasting which is not only time consuming, but adds possible user error when entering tags. F...
Guest over 3 years ago in Plant SCADA / Development Tools / Equipment 1

VSCode / Cicode Editor

Provide a language (Cicode) template / library that can be imported into VSCode. This would allow for some additional features that are sorely lacking in the Cicode editor. For example linting tools.
Guest over 3 years ago in Plant SCADA / Development Tools 2

Vendor supported tool to monitor client and server process availability

System availability is difficult to monitor on large systems and requires complex bespoke development. It would be good to manage all aspects of clients and server processes centrally.
Guest over 2 years ago in Plant SCADA / Kernel & Diagnostics 0

SOE Filter functions -SA Project template

The default SA Project template, comes with SOE list where system alarms and states are defaulted to be shown independent of any filter applied. From what I see this comes form the FUNCTION _AlarmPage_UpdateFilter() being set with "OR StateNumeric...
Guest over 3 years ago in Plant SCADA / Historic Data / Storage 0

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...