To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Realtime

Showing 17 of 697

Point Conditioning application should support point conditioning updates from multi threaded callers

[customer] experienced lock contention issues when updating point conditioning inputs from within ACE code. Investigation into this issue in support case https://gcsservicecloudutils.azurewebsites.net/casedetails?casenumber=960273706 and R&D I...
Andrew Potkins 5 months ago in Enterprise SCADA Server / Realtime 0

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest over 1 year ago in Enterprise SCADA Server / Replication 2 Waiting for information

ADE find/replace case sensitivity

Summary In 7.6, the Find was insensitive but the Replace was sensitive. This resulted in fewer rows being modified than what was found in the Find. In other words, it was a hidden defect. Making Find and Replace consistent was important to ensure ...
Josie Liu about 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 2 Will not implement

ADE permit to use symbols (),.-/

On ADE, Address1 and Address2 fields in the Station table of ADE do not permit the use of symbols such as (),.-/, even though these characters can be part of legitimate addresses.
Gerald Tseng about 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC 0

Allow protocol specific extensibility of dnlist ADE Form

The dnlist ADE form has protocol specifics built in for BSAP and Fisher ROC but does not allow any extensibility so it is difficult to add "Download by List" functionality to a new protocol (such as DNP3).
Collin Heggerud about 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC / Protocols and Commlines / Telemetry 1 Will not implement

Request for a new telemetered point type/table

SE PA WWW integrator has industry specific telemetered point type of Water Reservoir. Reservoirs are a type of telemetered point similar to an analog but with additional calculations for volume etc. Prior to binary release integrator modified the ...
Guest over 3 years ago in Enterprise SCADA Server / Realtime API/SDK / Realtime Schema / Telemetry 1

NMC should not log confusing messages if the ADLDS Cross Domain Replication sender is also a receiver from another ADLDS realm

The current 2023 system designs being provided to customers include an es/deployment system with it's own ADLDS realm. AOR area/group changes are made there first and it is the global table owner for its realm. The primary production system is set...
Hugh Arai over 1 year ago in Enterprise SCADA Server / Administration / Installation / Replication 0 Reviewing

GroupArea in the area table only contains the first 20 groups

Do we actually have a limit of 20 groups per area? Some testing has shown that one can add more then 20 groups into an area. The GroupAreaJoin table populates all of them correctly however the "group[0-19].name” array-field in the area table only ...
Bradley Tomanik almost 2 years ago in Enterprise SCADA Server / Administration / Installation / Realtime 1 Already exists

Request for year to be added to the runtime structure

We've previously added an additional "year" field to the runtime structure to track hours per year for a 7.5 project. I'd like to request an enhancement to OASyS 2021 to add "year" to the runtime structure please. I see that there's a runtimeyear....
Natalie Hunter over 3 years ago in Enterprise SCADA Server / Krunch and Data Manipulation / Realtime Schema 5 Will not implement

Collect doesn't collect current real-time value at top of hour

Customer Requirement Our customers require the ability to maintain complete Timeseries historical trends (collect samples), including timestamped samples polled after a PLC communication loss (outage could be for several hours/days). The customer ...
Guest over 3 years ago in Enterprise SCADA Server / Historical / Realtime 2 Waiting for information