Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

Status Will not implement
Portfolio area Enterprise SCADA Server
Products Datapump
Created by Rob Kenny
Created on Jun 1, 2023

Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts

We (TCE) would like to find out if Aveva would be able to enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts. We have turned bulk load off for now but would like to see if we could get this enhancement so we could switch back to the more efficient bulk load.

This is for the Waterfall SQL connector. It requires the triggers to fire to realize there is data to send. In testing we found that bulk insert is about 20 times faster

Background

TC Energy requires that insert triggers fire on both sites for all data inserted into the OASyS historian. Currently, the collect process uses the bulk insert FIRE_TRIGGERS option when placing the collect data into the owning site. However, when Datapump moves the data to the non-owning site, if bulk inserts are used, the FIRE_TRIGGERS option is not used and the triggers are not fired on the non-owing site.

Development Description

Enhance datapump to have a pre-table setting to turn on FIRE_TRIGGERS; this would be ignored if bulkload==0. If set, Datapump would set this option when doing the bulk insert for the table.

Expectation

Enhance datapump to have a pre-table setting to turn on FIRE_TRIGGERS; this would be ignored if bulkload==0. If set, Datapump would set this option when doing the bulk insert for the table.

Idea business value

Increase compatibility of datapump with Waterfall data diodes

Idea Type Improvement
Idea priority 4 – Important to my company
User Persona SCADA Administrator, IT/Network Administrator
Work in
OASYS-E-236 Enhance Datapump to be able to optionally use the FIRE_TRIGGERS option for bulk inserts
Work status
  • Attach files