1) Addition of an user option of outputting for calculation history in test output
If the ejector model cannot get convergent, the calculation history, especially for information for Compressed Vapor Pressure Calculated, Pc calc., is quite valuable to adjust the target Pc or pressure of entrainment vapor, Pe. Basically, Pc shall be automatically determined by temperature condition of the following surface condenser. Therefore, Pe shall be adjusted as a practical solution if not converged under given efficiencies.
2) Addition of Mach number of the mixed fluid after shock wave which was assigned by ‘M5’ in the original paper into output
In order to make sure validity of calculation results, it is necessary to confirm this Mach number whether the Mach number is under sound velocity or not at diffuser inlet and outlet.
3) Enhancement of the Help file and reference manual for the ejector
3-1) show the literature cited of the original paper. Namely H. El-Dessouky et al., Chem. Eng. and Processing, 41, 551-561 (2002)
3-2) addition of schematic drawing for pressure distribution and Mach No. distribution to understand the nomenclatures of the variables in the equations.
4) To apply user specified thermo model for calculation of isentropic factor (Cp/Cv) and heat balance
Ideal gas relation is applied for calculation of isentropic factor instead of user specified thermo model on PRO/II 2020 Pstch1. It induces large error for estimation of Cp/Cv of motive steam. Therefore, user specified thermo model shall be applied for Cp/Cv calculation as well as heat balance calculation which is related to the following Item 5).
5) Revision of estimation procedures of Cp/Cv of compressed vapor
A simple average rule is applied for estimation of Cp/Cv of compressed vapor using Cp/Cv of entrained gas and motive steam on ejector model of PRO/II 2020 Patch 1. However, this simple rule induces large error in Cp/Cv of compressed vapor. In order to improve calculation reliability, Ms. Yorke who is a technical leader of AVEVA Japan proposed quite smart calculation procedures of Cp/Cv of compressed vapor. Her proposal is based on (1) estimation of temperature of compressed vapor using given process conditions (T & P, component flow rates of entrainment gas and motive steam, pressure of compressed vapor), (2) estimation of Cp/Cv of compressed vapor using the estimated Temp and other conditions of compressed vapor. For design mode, every required conditions have already given before beginning of iteration. For rating mode, fixed assumed compression ratio (ex. 2.5 or 3) can be applied for estimation of pressure of compressed vapor which is required for estimation of Temperature of compressed vapor since the Cp/Cv of compressed vapor is not sensitive to pressure condition. Additional iteration can be avoided using this assumption for compression ratio.