We know that when kinetic energy calculations are enabled in APS Flare library we can observe situations where the pressure increases as a fluid slows down in an enlarger (decrease in fluid velocity). See below image from APS model that cannot be attached here:
Results in APS are correct and consistent also with Visual Flare but there is confusion because the reported pressure is not consistent with all other calculation apart flare library in terms of pressure. The objective is to add in Flare Enlarger model also the pressure calculation that dictates the flow direction. It will minimise confusion on how a forward flow can happen in fluid mode when the APS enlarger reported outlet pressure is higher than the inlet pressure
See more information below which shows our current understanding on the issue. Maybe some further clarifications are required:
When "Kinetic Energy" calculations are enabled the following type of pressures become distinguishable:
Static Pressure: is the pressure exerted by the fluid at rest, so at zero velocity. This is the one that sets the flow direction.
Dynamic Pressure: Kinetic energy per unit volume of a moving fluid This in APS is calculated when “kinetic energy” calculations are enabled. 
Total Pressure (or stagnation pressure): A good definition is the pressure a fluid will reach when it is brought to rest isentropically.

gamma = Cp/Cv, M = Mach number, P = Static pressure, Po = Stagnation Pressure.
APS calculates and displays the Static Pressure when “kinetic energy” is NOT enabled
APS calculates and displays the Stagnation (Total) pressure when Kinetic energy is enabled. I do not see in APS the “Static Pressure “ which dictates flow direction. My conclusion would be calculations are correct, especially after reading the “Enlarger” Help Note 2 and of course considering the VF/APS consistency.
The enlargement produces a net pressure recovery. Under reverse flow, the enlarger acts as a reducer, producing a net pressure loss. This means that the flow could be either positive or negative for a given pressure drop. Because of this, the enlarger will not work correctly when used without other pipes upstream or downstream of it.
My interpretation of this is that enlarger does not set the flow. Flows (forward or reverse) will be set by the in and out pipes.
If necessary we can provide the relevant APS 2025 model. Simx files are not allowed to be as an attachment: