Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

Status Received & categorized
Portfolio area Advisory Group Ideas
Created by Seiya Hirohama
Created on Jan 6, 2026

[On behalf of a customer] Liq. enthalpy using liq. heat capacity and ref. liq. enthalpy calculated by ideal gas enthalpy route

An option to calculate liq. enthalpy of each component by the following procedure which should work together with "ideal gas enthalpy route" for vapor enthalpy.

  1. Calculate liquid reference enthalpy {H (L,Tref,Pref) } at the reference temperature (Tref), using ideal gas enthalpy route:

H (L,Tref,Pref) = (ideal gas enthalpy) + (enthalpy departure by EOS) - (enthalpy of vaporization) ...(1)

  1. Calculate liquid enthalpy {H(L,T,Pref)} at a temperature (T) using liquid heat capacity and the above liquid reference enthalpy:

H(L,T,P)=(integration of Cp from Tref to T)+H (L,Tref) +(integration of vL from Pref to P)...(2)

Where, Pref would be vapor pressure of the component at Tref.

The 3rd term corresponds to Poynting Correction, and could be very small at the ambient pressure.

Idea industry Petrochemicals
Idea target user Plant engineer, Process Design Engineer
Idea priority 3 – Some use to my company
Idea business value

This method would useful when availability of heat of vaporization data is limited to a certain temperature range. (The method substantially "extrapolates" heat of vaporization from Tref using liquid heat capacity and ideal gas heat capacity)

  • Attach files