To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Drivers / Protocols

Showing 9

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 1

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Guest 22 days ago in Plant SCADA / Drivers / Protocols 0 Submitted

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest 23 days ago in Plant SCADA / Drivers / Protocols 0 Submitted

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 0

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest almost 3 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung over 1 year ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

S7TCP driver issue addressing arrays

Currently the S7TCP driver reads individual element of an array. Need functionality to read array as a whole
Guest 4 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

OPC UA Client - Multi Dimensional Array Tag

Are there any plans to support the OPC UA data type Multi Dimensional Array Tag?
Peter Chung over 1 year ago in Plant SCADA / Drivers / Protocols 0