To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 17 of 791

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román 4 months ago in Application Server / Device Integration / Other 0

Expand Auto-binding capabilities

Auto-binding has the potential to improve productivity significantly by removing the need for complex IO referencing scripts as well as allowing users to test IO assignment in runtime. Auto-binding today can only use the assigned IO device and Sca...
Ernst Van Wyk over 1 year ago in Application Server / Device Integration / IDE 1

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg 11 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Act as a REST/ WEB API server

Act as a REST API Server like the GR Access Tool for better integration with other products. GR Access Toolkit SDK needs to be written in .NET where REST API supports multiple programming languages.
Rainer Dsouza 8 months ago in Application Server / Device Integration 1

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest 12 months ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Create the DT suffix for the OI gateway to support the Date_And_Time data type from Siemens PLC in OPCUA

The DT suffix was present in the SIDirect communication driver and is now disappear in the OIGateway. This suffix permit to translate directly the data type Date_and_Time from the PLC and to the PLC with the object in the application server withou...
Guest 5 months ago in Application Server / Device Integration 0

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 8 months ago in Application Server / Device Integration 1

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1