Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 10 of 791

Invalid Timestamp Handling in IEC 60870-5-104 Driver within AVEVA Telemetry Server

In an energy remote control system, we are using the AVEVA Telemetry Server to read/write data from PLCs via the IEC 60870-5-104 protocol. During analysis of the communication frames, we have observed that, in some cases, values are received with ...
Jordi Román 4 months ago in Application Server / Device Integration / Other 0

Access to Object Wizard attributes

Make attributes on Choices and Option in the Object Wizard reachable from script. Complex script might be dependent on the choices made. Better to read the choice than to have several versions of the script assigned to each individual choice.
Jakob Drescher over 1 year ago in Application Server / Object Editor 2

Expand Auto-binding capabilities

Auto-binding has the potential to improve productivity significantly by removing the need for complex IO referencing scripts as well as allowing users to test IO assignment in runtime. Auto-binding today can only use the assigned IO device and Sca...
Ernst Van Wyk over 1 year ago in Application Server / Device Integration / IDE 1

Act as a REST/ WEB API server

Act as a REST API Server like the GR Access Tool for better integration with other products. GR Access Toolkit SDK needs to be written in .NET where REST API supports multiple programming languages.
Rainer Dsouza 8 months ago in Application Server / Device Integration 1

Create the DT suffix for the OI gateway to support the Date_And_Time data type from Siemens PLC in OPCUA

The DT suffix was present in the SIDirect communication driver and is now disappear in the OIGateway. This suffix permit to translate directly the data type Date_and_Time from the PLC and to the PLC with the object in the application server withou...
Guest 5 months ago in Application Server / Device Integration 0

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 8 months ago in Application Server / Device Integration 1

OPC UA Server - Export / Import

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to export / import tag configuration (structure). Easy possibility to export / import a defined...
Peter Rosenberger 8 months ago in Application Server / Device Integration 0

OPC UA Server - Network Adapter Selection

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to specify the network adapter for the OPC UA Server which is used for communication. It would ...
Peter Rosenberger 8 months ago in Application Server / Device Integration 0

Allow a Space in the EngUnits attribute field to turn on the attribute

Since the .EngUnits attribute for a Float or Integer is non existent until filled in, if you add a graphic into a template that references the .EngUnits it will show an error on the object when the .EngUnits is blank. There are times when we use t...
Jeff Scheer 9 months ago in Application Server / Object Editor 0

Allow attributes added to the choices and options to be seen in a middle column when highlighting the choice in the object or instance. Like it does in the template.

When opening an object or instance it would be nice to see what attributes are included in the wizard choice options. Like it shows in the template. I know it adds the attributes after checking the option but it's a pain to single out what it adde...
Jeff Scheer 9 months ago in Application Server / Object Editor 0