To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Make Inhibit State/Alarm Limits persist across redeployment of objects.

In all of our client's systems, we give them the ability to modify both the alarm limit/mode for analog alarms, and to inhibit tags that contain alarms (supervisors only). Problem is that if these tags are then redeployed without preserve runtime ...
Guest over 1 year ago in Application Server / Alarming 0

Build the TCP Listener application to run as a Windows Service

Providing the ability to run the TCP Listener application as a Windows Service would be useful to all SCADA projects that needs this feature.
Guest 6 months ago in Enterprise SCADA Server / Applications 1

Request for doc on how to configure Alarm mapping on AVEVA Historian Plant SCADA Connector documentation.

ADO Work Item #4782855 — [HELP] Alarm mapping on AVEVA Historian Plant SCADA Connector documentation. https://dev.azure.com/AVEVA-VSTS/_workitems/edit/4782855 DESCRIPTION We don’t have any information documented about the Alarm mapping details be...
Jake Hawkes 6 months ago in Historian & Client 0 In Roadmap

delay of model outputs

When a new recommendation is available from a model, the output property within AAA is updated but the associated stream in CONNECT receives the data with a delay. Furthermore, there is a delay between when the data would be pushed by CONNECT to P...
Hans-Otto Weinhold 6 months ago in Advanced Analytics 0 Needs review

remove stream data while re-training or back testing a model

When re-training and/or backfilling a model (back testing), data which is set as output parameters to be stored within CDS shall be wiped from the corresponding streams in CDS as otherwise data for the predicted objectives or topics will be very i...
Hans-Otto Weinhold 6 months ago in Advanced Analytics 0 Needs review

Modify the language DBFs from the Plant SCADA Studio

Instead of using Excel (or any other DBF editor) use the Plant SCADA Studio to modify the english.dbf, dutch.dbf of any other language . There is already a Setup -> Languages grid
Guest over 3 years ago in Plant SCADA / Development Tools 0 Reviewed & Categorized

Ability to train an anomaly model based on user input

As a consermer of alerts driven from an Anomaly score/Anomaly model. I'd like to be able to "tell" the model that a current alert or high score is or is not relevant to me. That way, the model will not score high for similar conditions in the future.
Jessica Rammo over 1 year ago in Advanced Analytics 0 Needs review

Priority option for properties

It can take a few minutes for new values to appear on a property. For example, a property mapped to an incoming sensor from CDS can take 3-5 minutes to see a new value that is added on CDS. AVEVA Advanced Analytics is not intended to be a real tim...
Guest about 2 years ago in Advanced Analytics 0 Needs review

IDE indicator for nearing the per-object Attribute limit

The MES OCO User Guide mentions this important note: An entity can have a maximum of 50 jobs. However, there is a limitation within System Platform that an object can have a maximum of 5000 attributes. Hitting this limit is quite feasible when usi...
Rob Budak about 2 years ago in Application Server / IDE 1

Runtime Manager to support staged startup, restart and shutdown of individual processes

Startup, restart and shutdown of an individual Citect process can be CPU and disk intensive. It would be great to be able to stage this, such that additional breathing space can be provided to other processes that run on the machine.
Guest over 6 years ago in Plant SCADA / Architecture / Clustering 0 Future Consideration