To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

wwClient update/fix

Hi everybody, for convenient troubleshooting of SuiteLink communication with drivers, it would be useful to have an upgraded version of the wwClient utility, which right now doesn't support encrypted SL (making it useless many times in SMS environ...
Mattia Popolla about 1 year ago in Device Integration 1 Will not implement

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 6 years ago in Device Integration 2

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 3 years ago in Plant SCADA / Alarms 2 Future Consideration

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle about 2 years ago in Device Integration 0 Planned

Respect user input from printform when selecting landscapemode

I've a customer that needs to print trends with 5 different vertical scales and therefore use the old TrendDsp functions. (Process analyst only supports 2 vertical scales). The Customer want to print these trends and selects a printer, color mode ...
Guest about 5 years ago in Plant SCADA / Alarms 0 Reviewed & Categorized

Process Analyst - Bar graph

It would be good to add also bar graph trends.
Ales B over 3 years ago in Plant SCADA / Alarms 0 Future Consideration

Alarms changes can be pushed to runtime without [Alarm]UseConfigLimits=1

When making alarm changes, sometime you will notice the change does not go through to runtime if you currently have [Alarm]UseConfigLimits=0 This is because the alarm server reads from the database instead of the rdb files, failing to recognize th...
Guest almost 2 years ago in Plant SCADA / Alarms 0 Future Consideration

Native Hardware and Process Historical Alarm logging in SQL database

As current scenario, we can't log historical alarm into SQL database natively. Using alarm category we can log but is has it own limitation. Native functionality like Alarm Upload of CitectHistorian can be real upgrade for CitectSCADA as industry ...
Guest over 6 years ago in Plant SCADA / Alarms 1 Future Consideration

SNMP-driver to support V3

From cybersecurity perspective end-users now have requirements to use V3, but this is currently not supported.
Guest 10 months ago in Device Integration 2