To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 42 of 859

Right click on a alarm - Navigate

I have a customer who wishes that users with insufficient privileges are not allowed to "Navigate" to the alarm. So basically. The same behavior as acknowledging and shelving that is greyed out (See the attached picture). Or at least have an optio...
Peter Chung almost 2 years ago in Plant SCADA / Alarms 0 Reviewed & Categorized

New alarm type (like Double point status alarm) which support 64 states

V2023R2 introduced the double point status alarm. This type of alarm can handle 8 different states. This very limited. Should be at least 32 states or preferrably 64.
Guest about 2 years ago in Plant SCADA / Alarms 1 Unlikely to implement

"Single Record" view of alarms

Combine ".Set", ".Clear" and ".Ack" records into a single record for simpler reporting. Possible today with SQL, but complicated. Better to have a targeted "extension table" for this use case. Also needed for REST Would be useful for the current A...
Elliott Middleton about 2 years ago in Historian & Client / Alarm & Event 2 Submitted

Reliable data collection from InTouch

Support reliable data collection for applications with InTouch and Historian, such as with Redundant Tag Servers. This should parallel how Redundant Engines and Redundant DI Objects work with Historian in a System Platform solution. A lower priori...
Elliott Middleton over 4 years ago in Historian & Client / InTouch 0 Submitted

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest almost 6 years ago in Plant SCADA / Alarms 3 Unlikely to implement

Create a Linux/containerized version of DMZ Secure Link

No description provided
Elliott Middleton over 3 years ago in Historian & Client / Install and Upgrade 0 Submitted

Leverage eDNA Historian as a Trend Data Storage Method in Citect

The eDNA History service is a high performance, lightweight historian. This Historian database would be a great replacement for the older flat file storage mechanism used by Citect. The eDNA historian would provide lossless, highly compressed stor...
Guest almost 6 years ago in Plant SCADA / Alarms 0 Future Consideration

Cluster field when adding a pen to the process analyst should be a pull-down menu

When adding a pen to the process analyst, it would be great if the cluster field was a pull down with the available clusters listed from the project. With multi-cluster projects, this would help filter out the trend tag lists, as the end-user does...
Guest about 6 years ago in Plant SCADA / Alarms 0 Future Consideration

Enumerated value tag type

Similar to a "discrete" with "message" strings, but with N integer states instead of just 0/1.
Elliott Middleton about 2 years ago in Historian & Client / Data Acquisition 0 Submitted

Indirect Tag for "SliceBy"

In our case (and I suspect others) we have many of the same type of equipment. It would be ideal to be able to specify a tag name pattern or something of that nature in the SliceBy call. This would avoid us having to iterate through a list of tags...
Elliott Middleton over 2 years ago in Historian & Client / Expressions 0 Submitted