To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 30 of 791

Right click on a alarm - Navigate

I have a customer who wishes that users with insufficient privileges are not allowed to "Navigate" to the alarm. So basically. The same behavior as acknowledging and shelving that is greyed out (See the attached picture). Or at least have an optio...
Peter Chung almost 2 years ago in Plant SCADA / Alarms 0

New alarm type (like Double point status alarm) which support 64 states

V2023R2 introduced the double point status alarm. This type of alarm can handle 8 different states. This very limited. Should be at least 32 states or preferrably 64.
Guest almost 2 years ago in Plant SCADA / Alarms 1 Unlikely to implement

Add support basic math operations on Equipment Editor

I have an equipment with "x" tags with fixed offset. In address field i try to use:equipment.tagA Address property "={equipment.HC900_Addressing[BaseAddress]} + {equipment.HC900_Addressing[Offset]}". equipment.tagB Address property "={equipment.HC...
Guest 9 months ago in Plant SCADA / Equipment 0

Add global equipment filter to the Plant SCADA Studio which applies to all tables

If you want to see the variable tags, trend tags, alarm or configuration parameters of one piece of equipment you have to apply an equipment filter for every type. If you could select an equipment filter in the top right of the Plant SCADA Studio ...
Guest 11 months ago in Plant SCADA / Equipment 0

The SA Treeview needs an option to hide the cluster node

One major use of clustering is for distributed processing on large sites. In this case it makes no sense for the cluster name to be part of the equipment tree as it may be arbitrarily assigned and named.
Guest about 1 year ago in Plant SCADA / Equipment 0 Submitted

Use TagInfoEx() to check whether an alarm exists

If you have an equipment type with an item and this creates a variable tag and an alarmtag you could use the TagInfoEx() function to check whether this item has an alarm defined. Let me give an example: Equipment:Motors.M1 Item:Run Variable Tag Na...
Guest almost 3 years ago in Plant SCADA / Equipment 0

Create new Trend Type that hooks into Variable Tag Subscriptions

Traditional periodic Trend type makes the end user set a very small sample time such that no sample is missed. This is a complete mis-match between what is happening at the tag level. I propose a new Trend type that hooks into the Tag Subscription...
Guest over 5 years ago in Plant SCADA / Alarms 3 Unlikely to implement

Leverage eDNA Historian as a Trend Data Storage Method in Citect

The eDNA History service is a high performance, lightweight historian. This Historian database would be a great replacement for the older flat file storage mechanism used by Citect. The eDNA historian would provide lossless, highly compressed stor...
Guest over 5 years ago in Plant SCADA / Alarms 0 Future Consideration

Cluster field when adding a pen to the process analyst should be a pull-down menu

When adding a pen to the process analyst, it would be great if the cluster field was a pull down with the available clusters listed from the project. With multi-cluster projects, this would help filter out the trend tag lists, as the end-user does...
Guest almost 6 years ago in Plant SCADA / Alarms 0 Future Consideration

Process Analyst Static Background

The process analyst does not currently allow for the layering of static imagine behind a trend. A customer would like to have the ability to set a background, similar to how regular trends in Citect SCADA operate. I believe this is currently not i...
Guest about 5 years ago in Plant SCADA / Alarms 0 Future Consideration