To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 35 of 776

Sort or filter S7TCP Tag Import

When using the Import Tags tool from the I/O Devices activity menu it lists all the available variables from the source PLC. It's not possible to sort or filter the list.
Liron Hallak about 1 year ago in Device Integration 1

MBTCP - add support for IEC1131 address format (%MW, %MX...)

The IEC1131 address format is already supported by Schneider OFS, but it would be useful to have it supported in MBTCP OI Server. It would make it easier migrating from other drivers to OI Server without changing addresses. Another advantage is al...
Florian Champalle about 1 year ago in Device Integration 0

Add support basic math operations on Equipment Editor

I have an equipment with "x" tags with fixed offset. In address field i try to use:equipment.tagA Address property "={equipment.HC900_Addressing[BaseAddress]} + {equipment.HC900_Addressing[Offset]}". equipment.tagB Address property "={equipment.HC...
Guest 8 months ago in Plant SCADA / Equipment 0

Is there any plan for OI Server to support SIMATIC S7-200 SMART?

SIMATIC S7-200 SMART is a cost-effective small PLC product tailored by Siemens for Chinese customers, and the SIMATIC S7-200 SMART firmware version has been upgraded to V3.0 this year. https://w2.siemens.com.cn/smart/Product/S7
Shaobao Hu 9 months ago in Device Integration 1

Add global equipment filter to the Plant SCADA Studio which applies to all tables

If you want to see the variable tags, trend tags, alarm or configuration parameters of one piece of equipment you have to apply an equipment filter for every type. If you could select an equipment filter in the top right of the Plant SCADA Studio ...
Guest 10 months ago in Plant SCADA / Equipment 0

The SA Treeview needs an option to hide the cluster node

One major use of clustering is for distributed processing on large sites. In this case it makes no sense for the cluster name to be part of the equipment tree as it may be arbitrarily assigned and named.
Guest about 1 year ago in Plant SCADA / Equipment 0 Submitted

SNMP AES v3

Hi Team, more and more customers are looking to integrate network devices or power devices in system platform via SNMP. But these devices utilize v3 AES most cyber secure encryption mentor. Our drivers only support DES at the moment leading the cu...
Lakshay Mundeja about 1 year ago in Device Integration 2 Planned

OPC A&E (and/or OPC UA A&C) to support Areas

We have alarms split into several Areas. When we connect using an OPC AE Client it only shows the correct custom properties for alarms with Area 0. Seems the integrated OPC A&E Server connects to the Alarm database with a user which only can v...
Guest over 3 years ago in Device Integration 1

Mitsubishi FX5U PLC driver for Plant SCADA

MELSECQ protocol can be used to communicate with FX5U, but the addressing system is different. MELSECQ expects Hexadecimal addressing while FX5U expects Octal addressing system.
Jiri Rysavik over 1 year ago in Device Integration 0

How to communicate between Plant SCADA and OMRON PLC NJ series

Among Korean Plant SCADA users, there are often users who use Omron NJ series PLC. They express great inconvenience and dissatisfaction about the lack of communication between Plant SCADA and Omron NJ PLC. The method of changing the address of KB0...
Guest over 1 year ago in Device Integration 0