Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 776

Support multiple cores for InTouch

Introduce support for distributing the processing load across multiple cores for InTouch for better utilization of resources and performance.
Mohammad Azhar over 1 year ago in InTouch HMI 0 Planned

Alarms changes can be pushed to runtime without [Alarm]UseConfigLimits=1

When making alarm changes, sometime you will notice the change does not go through to runtime if you currently have [Alarm]UseConfigLimits=0 This is because the alarm server reads from the database instead of the rdb files, failing to recognize th...
Guest 12 months ago in Plant SCADA / Alarms 0 Submitted

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 7 months ago in Application Server / Device Integration 1

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle about 1 year ago in Application Server / OCMC (Previously SMC) 0

Support for flowtotals as flowpath input into pressmon

Support for flowtotals as flowpath input into pressmon.
Andrew Potkins about 2 months ago in Pipeline Operations for Liquids 1

Ability to choose timezone of dates and times in UI

When investigating something like an anomaly score for a plant located in a different timezone than the user, it can be confusing to try to line up anomaly spikes with what is happening in the plant. It would be nice to be able to configure a diff...
Jessica Rammo 9 months ago in Advanced Analytics 0 Needs review

Symbol Editor: Text Box should scale the same as Text

Text box embedded in a graphic that is embedded and manually scaled (drag corner to change size) does not scale the font. Additional info is in: SR: 960592245 ER: 3912243
Guntars Rubenins 7 months ago in Application Server / Visualization 1

Increase Object Containment Level Limit from 10 to 50+

Increase the Object (and Area) Containment Level Limits from 10 to 50 or more. Today we cannot model more than 10 cascaded containment Objects, and we are forced to treat Areas as Objects to adequately represent electrical hierarchy of our power p...
Keary Dosier 4 months ago in Application Server / Configuration 0

Get Custom Property Reference by script

Allow retrieving a reference from a custom property to reuse it in a graphic. Example: indicate to the user the attribute used in a display and be able to find it in Historian.
Hugues Alexis 9 months ago in Application Server / Scripting 0

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest almost 3 years ago in Plant SCADA / Equipment 3 Unlikely to implement