To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 591

Cannot access AEL UI when customer SMS port is used

When installing AEL version 4.0.1 and activating secure mode, if a non-standard SMS port is used, the URL becomes unreachable. Although the manual provides steps to address this issue, it would significantly improve user experience if this configu...
Peter Chung about 1 month ago in Plant SCADA / Other 0 Submitted

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 2 years ago in Plant SCADA / Alarms 0 In Roadmap

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 1 year ago in Plant SCADA / Development Tools 0

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0

Fontsize ciode form functions

The posibility to change the fontsize, font used in the cicode form functions.
Guest 11 months ago in Plant SCADA / Graphics / Visualization 0

InTouch: add configurable item name prefix for Access names

It would be very useful to be able to configure an item name prefix for each Access Name. This prefix would be added to the "item name" of each tag configured to use the given Access Name. If you want InTouch to communicate with Siemens S7-1200 or...
Florian Champalle about 2 months ago in InTouch HMI 0

Update of change of user-info across network

When changing passwords or adding users, this is currently not automatically copied to other operator-stations in the network. As I understand it we need to add a function that adds the changes, then do a partial compile. This should be a standard...
Guest 3 months ago in Plant SCADA / Other 0

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest almost 2 years ago in Plant SCADA / Equipment 1 Future Consideration

Windows should have icons to indicate presence of scripts

I often need to migrate older InTouch applications to the latest version. Every time, the applications have scripting, but also window scripts and action scripts (buttons for example). It would save a lot of time if the UI would indicate what wind...
Rares Plesea about 2 months ago in InTouch HMI 0

Process Analyst - Bar graph

It would be good to add also bar graph trends.
Guest over 1 year ago in Plant SCADA / Alarms 0 Future Consideration