To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 791

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 2 years ago in Plant SCADA / Alarms 2 Future Consideration

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest almost 6 years ago in Device Integration 2

Object Performance Index

Helping users understand the resource requirements Most aspects of perfromance is dependent on the object's complexity, but there is no good way to measure that complexity. This is also required to help with the queuing mechanism described above, ...
Ernst Van Wyk over 1 year ago in Application Server / Application Server Runtime / IDE 0 Planned

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

Add a user friendly name in the AEL for devices using RDS

When using Plant SCADA with RDS it is difficult to recognize which session is consuming which license in the AEL, this makes it hard to troubleshoot licensing problems. In other products the situation is even worse where no session informaiton is ...
Liron Hallak about 1 year ago in Plant SCADA / Other 0 Submitted

Increase Object Containment Level Limit from 10 to 50+

Increase the Object (and Area) Containment Level Limits from 10 to 50 or more. Today we cannot model more than 10 cascaded containment Objects, and we are forced to treat Areas as Objects to adequately represent electrical hierarchy of our power p...
Keary Dosier 5 months ago in Application Server / Configuration 0

Alarm Page and Historical SOE list with Time filter

We are getting complaints from customer that the Alarm Page and Historical SOE do not have to capability to filter lists on Time. This case has been discussed in the Community . And there has been several feedbacks form the Community to AVEVA on t...
Guest about 4 years ago in Plant SCADA / Historic Data / Storage 2

Secured and Verify Writes popup for boolean shoud show Onmsg/Offmsg instead of True/False

The popup for secured/verify writes is showing the value True or False. Would be more logical that it uses the OnMsg or OffMsg that is configured for the corresponding attribute.
Lauran Lint 12 months ago in Application Server / Security 0

Enable drag&drop assignment of Alarm Groups for UDT instances

Currently it is possible to drag a Tagname Dictionary tags and drop it into a GroupVar / Alarm group via "Model - Tagname" panel. The same is not possible for UDT instances. We'd like to have it.
Pavel Prusa 5 months ago in InTouch HMI 1 Planned