To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Plant SCADA

Showing 107 of 597

Deployment supporting Terminal Server and Profiles

Deployment is not officially and 100% supporting Terminal Server systems. Supporting this by the Deployment Server and also the possibility to select a Profile for the Terminal Server and not is needed.
Guest almost 5 years ago in Plant SCADA / Development Tools 1 Future Consideration

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest almost 2 years ago in Plant SCADA / Equipment 3 Unlikely to implement

Respect user input from printform when selecting landscapemode

I've a customer that needs to print trends with 5 different vertical scales and therefore use the old TrendDsp functions. (Process analyst only supports 2 vertical scales). The Customer want to print these trends and selects a printer, color mode ...
Guest about 3 years ago in Plant SCADA / Alarms 0

Event Type Trends shows last good value during communication failure

*Form last 3 to 4 years we have been selling and proposing Citect Scada with DNPr driver in Pharmaceutical Companies as a 21CFR compiled Solution. We are using the back-filling feature of DNPr driver with Citect Scada. To use this feature we confi...
Guest over 4 years ago in Plant SCADA / Alarms 0 Future Consideration

A function to get the number of display clients connected to a server process

Existing ServerInfoEx() function gives the number of server side Trans of a specified service type but there is no way to get the number of display clients connected to a server.
Guest over 4 years ago in Plant SCADA / Other 0 Future Consideration

Enlarge the tables in the kernel

For instance the CSAToPSI.Subs, it starts with the cluster name, then the tag, which can 79 characters. You can only see 29 characters. Also in a kernel dump the length is limited. Also sorting on different colums would be helpfull.
Guest almost 2 years ago in Plant SCADA / Kernel & Diagnostics 0

deployment on offline client

To have better use of implementing deployment in our system, i need to update clients that are not on and use in daytime. For instance a laptop can get a message that upgrade is possible and can initiate latest version.
Guest almost 5 years ago in Plant SCADA / Other 0 Future Consideration

Citect Studio - Insert Row, Insert Rows

There is no option to insert a new row record. Such an option could be useful. This can be done by DBF addin excel.
Guest about 2 years ago in Plant SCADA / Development Tools 0

Push all data type of Variables to AVEVA Historian

Currently, The CitectSCADA connector reads Trend tags, SPC, Alarm tags, and Variables (String and Digital data type) info from Plant SCADA and writes data to AVEVA Historian. It would be better to have other data type variables, like Int, Long, re...
Guest about 1 year ago in Plant SCADA / Other 3 Unlikely to implement

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest over 1 year ago in Plant SCADA / Development Tools 0