To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 34 of 859

[PlantSCADA] Ability to Historize other Data Type (like INT/REAL)

4.1 Be able to Historize other Data Type (like INT/REAL) of tag variables , not just the Digital/String Data Types Looks like this is done by choice or some other reasons, e.g. name clashes. The Connector code currently explicitly filters out vari...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

AVEVA Historian official support for Proxmox VE

I would like to propose the inclusion of Proxmox Virtual Environment (VE) as a supported hypervisor platform for AVEVA Historian. Proxmox VE is a robust, open-source virtualization solution that combines KVM and LXC with a powerful web interface a...
Jeffrey Tambach 6 months ago in Historian & Client / Install and Upgrade 0 Submitted

OPCUA Variable Import limited to 79 characters

When you import Variable Tags from an OPCUA Server the tag names are truncated to 79 characters, this is sometime not enough. Duplicate tagnames are not allowed. You have to manually adjust all the names. For instance when you connect to a Plant S...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1 Reviewed & Categorized

Modify the S7TCP driver to support S7 PLCSIM Advanced

Modify the S7TCP driver to support S7 PLCSIM Advanced
Peter Holmberg about 1 year ago in Plant SCADA / Drivers / Protocols 0 Submitted

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Bundle UA Server Expert Instead of OFS with PlantSCADA

OFS is bundled with Citect so it can be installed on the same machine and use the Citect license. But it just feels wrong introducing an OPC DA server when Schneider now have the UA server expert. My idea would be to bundle UA Server Expert with P...
Guest about 1 year ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1 Reviewed & Categorized

Enhance the OPC UA server browsing feature in AVEVA Plant SCADA to allow batch selection and import of multiple tags simultaneously, improving efficiency for users handling large tag sets

The current OPC UA server browsing feature in AVEVA Plant SCADA only allows users to browse and import tags one by one. This process is not feasible when dealing with large systems containing thousands of tags, as it significantly increases the ti...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 In Roadmap

[PlantSCADA] Better support for tag config changes on PlantSCADA end

4.3 Changes to Plant SCADA configuration Where there are changes from the PlantSCADA side, a restart of the connector is required however there are many cases of where the users forget to do this. A reminder message may help. Looks like this is do...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

[PlantSCADA] Fault tolerance to errors on the PlantSCADA side

2.0 Fault Tolerance of the connector to SCADA misconfiguration If there is a misconfiguration on the SCADA side, for example after the system is running, then it can lead to the ctapi connection being dropped and no logs for all tags, and not just...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 1 In Roadmap