Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 11 of 791

Omnicomm should better support modern network speeds

Omnicomm has a feature that allows it to wait longer for large messages than for short messages. This feature defaults to calculations based on messages transmitted at 1200bps and has a maximum configurable rate of 38400bps. In a world where many ...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm 0

Omnicomm retries on temporary connections should retry the connection

On Tech Support case 962469169 it became very clear that when the socket of a temporary connection was broken, Omnicomm would not re-attempt the connection until the next scheduled poll interval (e.g., 5 minutes later). I would expect that if Omni...
Collin Heggerud 3 months ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines 0

Dnaswana with DALPrompter

Big Picture User Experience Enable SCADA Administrator to use a centralized server to monitor and troubleshoot communications on multiple systems. Detailed Description To enhance security and reduce server resources, customers typically install mo...
Vitali Unke almost 2 years ago in Enterprise SCADA Server / Architecture / Omnicomm / Security and DMZ 0 Reviewing

Initialize the memory of a variable when switched On using Director command

In Connoisseur we had the capability to re-initialise a specific variable when switching it ON. That is, delete its previous variation history to clear out any inconsistent or untypical behaviour (eg startup). This functionality should be enabled ...
Jan Ledwon almost 3 years ago in APC / General 0 In development

Add ability for Omnicomm to support secure connections to devices

Enterprise SCADA desires to be at the forefront of security. Many protocols are beginning to support SSL/TLS connections to the end device, thus finally protecting that last few feet of communications from the networking equipment to the device. F...
Collin Heggerud almost 2 years ago in Enterprise SCADA Server / API / SDK / Developer Relations / Omnicomm / Protocols and Commlines / Security and DMZ 7 Reviewing

Standard Deviation function for custom calculations

We often need to use SD in calculations. However it is not a standard function available under custom calculations. Please can we add it there.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Excel Data import improvements

New feature in 2022 SP1 works great already, but some suggestions for further development: allow import from multiple sheets of Excel workbook if tagname is missing for a particular column, substitute a default (currently the data gets mis-aligned...
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

Convert Raw Tag to Custom

Currently it is possible to convert a Custom Tag to Raw Tag, but not vice versa. This would be v helpful when migrating controllers.
Geoff Lewis over 2 years ago in APC / General 0 Evaluating

IEC-104

IEC60870-101 or IEC60870-104 are the serial and IP versions of what is sometimes refered to IEC-104. These are both part of the IEC60870-5 standard, whereas ICCP is IEC60870-6, and is different. IEC_62351 is a standard for securing the various pro...
Josie Liu almost 6 years ago in Enterprise SCADA Server / Omnicomm / Protocols and Commlines / Telemetry 0 Reviewing

Enhance Omnicomm to make it easier for protocols to work with sub-remote status indicator.

An enhancement for protocol developers that is standard for all protocols.