To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest over 4 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

Add a parameter to modify the automatic logout time of the deployment server

One of our SI's reports that it is very annoying to be automatically logged out of the Deployment server in the Citect studio. This is set to 10 minutes by default. I've checked with AVEVA support about this, but there is currently no parameter av...
Guest over 4 years ago in Plant SCADA / Development Tools / Other 0 Future Consideration

Put ArchestrA Graphics back in a separate tab like in old versions

No description provided
Vincent TOUBLANC over 1 year ago in Application Server / IDE 3

A function to get the number of display clients connected to a server process

Existing ServerInfoEx() function gives the number of server side Trans of a specified service type but there is no way to get the number of display clients connected to a server.
Guest almost 6 years ago in Plant SCADA / Other 0 Future Consideration

Expand gas measurement krunch items beyond arbitrary limit of 1022

Meter config upload limits hard-coded based on older Mercury devices and don't support newer Mercury devices. I believe this is a defect in the API, but have been asked to submit as an enhancement.
Collin Heggerud 4 months ago in Enterprise SCADA Server 0

Alarm Summary display should have a safer mechanism to acknowledge alarms to assure the correct alarm is being acknowledged

http://tcjira.aveva.com/browse/PMFR-479 is the latest ask. This has been requested many times
Jake Hawkes almost 3 years ago in Enterprise SCADA HMI 1

Make Inhibit State/Alarm Limits persist across redeployment of objects.

In all of our client's systems, we give them the ability to modify both the alarm limit/mode for analog alarms, and to inhibit tags that contain alarms (supervisors only). Problem is that if these tags are then redeployed without preserve runtime ...
Guest 11 months ago in Application Server / Alarming 0

Enable drag&drop assignment of Alarm Groups for UDT instances

Currently it is possible to drag a Tagname Dictionary tags and drop it into a GroupVar / Alarm group via "Model - Tagname" panel. The same is not possible for UDT instances. We'd like to have it.
Pavel Prusa 8 months ago in InTouch HMI 1 Planned

Import tool between OPC UA Hierarchies and InTouch UDTs

OPC UA exposes full hierarchical structures, including data types, comments, and nested relationships. This is conceptually similar to User Defined Types (UDTs), which also provide structured, named data types and hierarchies. Currently, InTou...
Pavel Prusa 8 months ago in InTouch HMI 1 Planned

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Ales B over 2 years ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement