To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Ability to store the output of Expressions into a new tag

Configure a new tag with its source being the output of an expression. Point would update when any of the source points updated.
Jake Hawkes 7 months ago in Historian & Client / Data Acquisition / Expressions 0 Submitted

SNMP-driver to support V3

From cybersecurity perspective end-users now have requirements to use V3, but this is currently not supported.
Guest 10 months ago in Device Integration 2

Possibility to modify values directly in the SIM OI-Server

For testeing purposes, the OI-Server SIM can be handy. The only missing thing here is the possibility to modify values directly through the UI of it. I now use the WWClient to do this to get the values I want in my Galaxy environment. A added valu...
Lauran Lint over 1 year ago in Device Integration 0

Citect S7TCP driver to be updated.

CITECT S7TCP driver is not able to communicate with Siemens PLCSIM Advanced V5.0 while other SCADA Software are able to do so.
Guest over 3 years ago in Device Integration 2

Create the DT suffix for the OI gateway to support the Date_And_Time data type from Siemens PLC in OPCUA

The DT suffix was present in the SIDirect communication driver and is now disappear in the OIGateway. This suffix permit to translate directly the data type Date_and_Time from the PLC and to the PLC with the object in the application server withou...
Guest over 1 year ago in Device Integration 2 Will not implement

Change the IP address of a controller using a parameter for S7TCP and other protocols

For communicating with S7 controllers you would use PSDIRECT in the past. For this protocol the IP Address of the controller is in the backend configuration. For S7-1500 you can use S7TCP, this has the IP address in the Address field of the I/O De...
Guest almost 4 years ago in Device Integration 0

Siemens PLCSim advanced Support for OI SI Direct driver

Currently the OI SI Direct driver does not support symbolic communication with Siemens PLCSim Advanced. Symbolic adressing is the way forward, legacy adressing is a security issue and not reccomended going forward. In adddition to that legacy adre...
Eirik Ødegård almost 2 years ago in Device Integration 0 Planned

[PlantSCADA] Better support for tag config changes on PlantSCADA end

4.3 Changes to Plant SCADA configuration Where there are changes from the PlantSCADA side, a restart of the connector is required however there are many cases of where the users forget to do this. A reminder message may help. Looks like this is do...
Marcell Marjee about 1 year ago in Historian & Client / Data Acquisition 0 In Roadmap

[PlantSCADA] Fault tolerance to errors on the PlantSCADA side

2.0 Fault Tolerance of the connector to SCADA misconfiguration If there is a misconfiguration on the SCADA side, for example after the system is running, then it can lead to the ctapi connection being dropped and no logs for all tags, and not just...
Marcell Marjee about 1 year ago in Historian & Client / Data Acquisition 1 In Roadmap

[PlantSCADA] Make connector activity visible in PlantSCADA UI

The main issue is that if you stop Plant SCADA while a backfilling operation is ongoing but the Connector is still working, then we get the issue that data is written on wrong blocks into historian. To successfully complete the backfill operation,...
Mats-Peter Cansund about 1 year ago in Historian & Client / Data Acquisition 3 In Roadmap