To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

All ideas

Showing 837 of 837

Upgrade the MAXIMUM LENGHT for STRING and CITECT.INI Parameters over 254 characters !

As discussed in TN000028481 , the MAXIMUM LENGHT for STRING and CITECT.INI Parameters is 254 characters ! This cause many problems inside CICODE SCRIPTS (this limit is too strong in modern world!) and in [Event] parts of citect.ini (you must reduc...
Guest almost 3 years ago in Plant SCADA / Development Tools 0 Reviewed & Categorized

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest almost 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Display quality as string intead of Hex in OCMC (SMC)

Hex value indicating the quality of the items in OI Server Device Groups (Diagnostics) is not easily readable. I suggest to replace the Hex values by their String value, or display Hex value and string value like in Object Viewer (eg: C0:Good)
Florian Champalle over 1 year ago in Device Integration 0

Alarms changes can be pushed to runtime without [Alarm]UseConfigLimits=1

When making alarm changes, sometime you will notice the change does not go through to runtime if you currently have [Alarm]UseConfigLimits=0 This is because the alarm server reads from the database instead of the rdb files, failing to recognize th...
Guest about 1 year ago in Plant SCADA / Alarms 0 Future Consideration

Process Analyst in dark mode

A complete dark Mode of the Process Analyst is not possible. Some parts of the PA can’t be changed. There are no properties to change the background and foreground color of the toolbar and object view.
Guest over 2 years ago in Plant SCADA / Alarms 2 Future Consideration

Custom Namespaces values in Object Viewer

Enable the ability to view the runtime values of Custom and Standard Namespaces in the Object Viewer.
Luca Preziosa 9 months ago in Application Server / Diagnostics 1

Search and replace inside Equipment Editor

When we have diferent equipments with same comun branch and need to change them all, its a lot of work, because we need t go to each equipment open it search the item, open it and change.
Guest almost 6 years ago in Plant SCADA / Development Tools / Equipment 0 Future Consideration

Expression support in Values of attributes including settings

Allow Expression support in Value IO reference Settings of Object wizards (e.g. TrendHi = EngUnitsMax*1.1 This should also supply the capability described in APPSERVER-I-202 We have a customer that needs to use scripting to create custom attribute...
Ernst Van Wyk over 1 year ago in Application Server 0

Compatibility Testing: Aveva software & AI-Based AV — CrowdStrike

Based on the latest trends in cybersecurity and the higher industry requirements, it would be beneficial to have more options for Antivirus (AV) software that could be tested in a controlled environment with AVEVA software. Not having the vendor e...
Guest 5 months ago in Application Server / Security 0 Planned

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest almost 6 years ago in Device Integration 2