To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 33 of 776

Add 64-bit INT to Modbus Driver

Device manufacturers (especially Schneider) are increasingly using 64-bit integers for data. The present Modbus TCP driver does not support 64-bit INT so integration of these devices results in unsatisfactory limits on data. The Modbus driver need...
Guest over 2 years ago in Plant SCADA / Drivers / Protocols 1

Reading 64-Bit Double (Float) in OPC UA as a String

Energy meters and sensors often are using IEEE double precision (64 bit) floating point datatypes for counters and totalizer. Reading this Items as a string from the OPC server and then convert it in a Real Data type Cicode Variable can allow us ...
Guest over 5 years ago in Device Integration 2

OPCUA Client / HA

Add to the existing OPCUA driver also the HA (Historical Access)
Ales B over 2 years ago in Plant SCADA / Drivers / Protocols 1 Unlikely to implement

Driver Statistics

It would be nice have a Cicode interface that would allow engineers to query driver statistics. For example, group poll times from an abclx device.
Guest about 4 years ago in Plant SCADA / Drivers / Protocols 4 Future Consideration

IMS 2459104 KNX ETS 5.100 fan stage support

A customer requested support for KNX ETS 5.100 fan stage support
Peter Chung 7 months ago in Device Integration 0

Change the IP address of a controller using a parameter for S7TCP and other protocols

For communicating with S7 controllers you would use PSDIRECT in the past. For this protocol the IP Address of the controller is in the backend configuration. For S7-1500 you can use S7TCP, this has the IP address in the Address field of the I/O De...
Guest almost 3 years ago in Device Integration 0

BACnet Object Type Trend not supported

A customer who relies on the BACnet driver have found that the absence of a standard Object Type Trend is a significant limitation to their project. We would greatly appreciate your consideration of this enhancement request, and we look forward...
Peter Chung over 2 years ago in Plant SCADA / Drivers / Protocols 1 Future Consideration

Citect S7TCP driver to be updated.

CITECT S7TCP driver is not able to communicate with Siemens PLCSIM Advanced V5.0 while other SCADA Software are able to do so.
Guest over 2 years ago in Device Integration 2

The OPC UA driver should be able to read Tags, Alarms and Events

The OPC UA driver should be able to read Tags, Alarms and Events from other Scadas (iFix, Cimplicity, WinCC, Etc)
Guest almost 2 years ago in Device Integration 1

S7TCP driver does not talk to PLCSIM Advanced

Not sure why my previous submission was deleted, so I send again. S7TCP driver needs update to resolve the issue with the communication with Siemens PLCSIM Advanced simulator while other SCADA software can easily talk to it.
Guest over 2 years ago in Device Integration 1