Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 32 of 776

Stop modifying Industrial Graphics when opening WindowMaker

Every time WindowMaker is opened, all Industrial Graphics get touched with a new date/time. This results in NAD or manual sync operations sending all the graphics each time despite nothing actually having changed.
Andrew Flournoy about 1 year ago in InTouch HMI 0

Make Alarm Hotbackup Manager fully integrated into InTouch

The utility named Alarm Hotbackup Manager isn't a service nor needs to stay running. It simply makes an INI that is utilitized by InTouch runtime. Then alarms are sycned via an inocuous alarm grid with a query calling for said named pair. Why isn'...
Andrew Flournoy over 1 year ago in InTouch HMI 1

Document public FNput commands for Remote and connection records

Remote and connection tables have supported public commands called FNPuts. Through these commands 3rd party application (and internal) invoking commands. Such as TestPoll or a request to poll now. Although Documentation list number of FNPut comman...
Vitali Unke about 1 year ago in Enterprise SCADA Server / Realtime 0

DB dump load window

Please modernize the DB dump and load dialog. This is still circa Windows 3.1.
Andrew Flournoy over 1 year ago in InTouch HMI 1 Planned

CRM Point to Point Verification Enhancement

To address PHMSA finding and to improve commissioning experience, we are looking to add the following data fields to CRM database and improve the existing display to support the fields. Field (with examples) Description Engg Units (Pull from datab...
Guest almost 2 years ago in Enterprise SCADA Server / Applications 0

Request for a new telemetered point type/table

SE PA WWW integrator has industry specific telemetered point type of Water Reservoir. Reservoirs are a type of telemetered point similar to an analog but with additional calculations for volume etc. Prior to binary release integrator modified the ...
Guest almost 4 years ago in Enterprise SCADA Server / Realtime API/SDK / Realtime Schema / Telemetry 1

Analog field rawval should be replicated to non-owning sites

Client has observed that the ANALOG "rawval" field is not replicating to non-owning sites; and they expect this value to be replicated. Anything else relevant to this feature? There is an optional feature called the "Raw Data Enhancement" RAW_ENAB...
Guest about 2 years ago in Enterprise SCADA Server / Replication 2 Waiting for information

Expose scripts in Industrial Graphics

When printing an application, this allows us to understand all scripts in InTouch. Anything within Industrial Graphics isn't included. There should be a mechanism to show all scripts in the graphics for troubleshooting and optimization.
Andrew Flournoy about 1 year ago in InTouch HMI 1

ADE find/replace case sensitivity

Summary In 7.6, the Find was insensitive but the Replace was sensitive. This resulted in fewer rows being modified than what was found in the Find. In other words, it was a hidden defect. Making Find and Replace consistent was important to ensure ...
Josie Liu over 2 years ago in Enterprise SCADA Server / ADE / PnT / MoC 2 Will not implement

ADE permit to use symbols (),.-/

On ADE, Address1 and Address2 fields in the Station table of ADE do not permit the use of symbols such as (),.-/, even though these characters can be part of legitimate addresses.
Gerald Tseng over 1 year ago in Enterprise SCADA Server / ADE / PnT / MoC 0