Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Remove more than 1 version in the deployment server at a time

It would be highly beneficial to introduce the capability to remove multiple versions simultaneously. Additionally, an automated feature to retain only the latest 10 versions.
Peter Chung over 2 years ago in Plant SCADA / Other 1 Reviewed & Categorized

Improve Text input controls in OMI

Improve user controls that enable text inpout inside OMI. Controls like text inputs still behave like the early days of InTouch where it was interesting to indicate to user he clicked and there is something to input. In modern User Interfaces inpu...
Mathieu VANTARD 8 months ago in Application Server / OMI web runtime 0

Remove the Need for pg* Files

Eliminate the requirement for pg*.dbf files. These files are not really needed as the same info is in the .ctg files. These files make it difficult to use PlantSCADA with version control, such as SVN or git since either these files need to be vers...
Will Herndon over 4 years ago in Plant SCADA / Graphics / Visualization 1 Reviewed & Categorized

Allow IO feature for array attributes

When using the object editor, the IO feature is not available for array types. Reading array data is very basic functionality and the inability to do this creates very messy objects.
Andrew Drane 9 months ago in Application Server / Object Editor 1

Bulk Copy of Custom Property Values Between Embedded Symbols

Problem Statement When two embedded symbols in the graphics editor share identical custom property definitions but differ in their default values, users must manually enter the correct default values for each property in the target symbol. This ma...
Ernst Van Wyk about 1 year ago in Application Server / Graphic Editor 0

Add filter and sort options in the Cross References screen

Being able to filter and sort in the Cross References screen of the object properties would make it substantially easier to have an overview of certain attribute usages. Right now you cannot group the references by attribute for example, which mak...
Bob Eeckhout over 1 year ago in Application Server / IDE 0

In the IDE, open up multiple selected object instances instead of one at a time.

Currently, you can only open and check out one object instance at a time. Make it so that we can open multiple selected object instances at a time for editing.
Roan Fourie almost 2 years ago in Application Server / IDE 1

Modifications to Persistent Memory Device without downtime

Structural changes to Persisted Memory tags (such as modifying the array size) cannot be applied while any I/O server hosting that device is still running. A brief coordinated stop of all I/O servers is the required procedure. When an I/O server s...
Guest 4 months ago in Plant SCADA / Drivers / Protocols 0 Submitted

Ability to rename security roles

When during upgrade, new servers are created in a new domain, the roles defined in the galaxy when using OS Group Authentication become invalid because their names follow the format: <Domain name>\<OS Group>. In a galaxy with many secu...
Bendt Hejbøl 10 months ago in Application Server / IDE 0

Implement Quickscripts for OMI and OMI web client

InTouch has a concept of reusable quick scripts. We need that for Application server as well as for OMI and OMI web client. Especially for use in OMI web client, these "quick scripts" should be able to: Execute local (in browser) or remote (on ser...
Ernst Van Wyk about 2 years ago in Application Server / Application Server Runtime / OMI desktop runtime / OMI web runtime 1 Planned