To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Call Excel Addin functions from vba

Whe have our own Excel macro's for generating tags, alarm, trends, etc and would like to use the 64bit version of Excel. We want to open a DBF using the Excel Addin, run our own macro and then save the DBF file using vba.
Guest over 2 years ago in Plant SCADA / Development Tools 1 Future Consideration

Conditional Tag Generation for Empty Addresses

Many equipment are almost identical, but not every signal exists for every equipment. Without this rule, SCADA generates unnecessary tags for empty addresses. These dummy/internal tags still get compiled and loaded at runtime, which increases tag ...
Guest 4 months ago in Plant SCADA / Equipment 0 Submitted

Faster compiler

The old compiler needs to utilize modern hardware better to decrease compile-time. Also applies to other tools who I suspect uses same/similar routines working with DBFs and such. Like page update and packing, etc.
Guest about 3 years ago in Plant SCADA / Development Tools 0 Future Consideration

Support for individual navigation on multiple screens with NavTreeControl or NavBreadcrumbControl

Today the navigation apps are linked to asset. If used on multiple layouts/screens all set the same asset to the Navigation namespace. This makes the navigation apps on all screens to change to the same item. I would like to have an option to use ...
Øyvind Hansen about 1 year ago in Application Server / Other OMI apps 0

Allow flashing and color configuration for individual columns in OMI alarm app

Ability to choose whether color and blinking applies to entire row or selected column - at least for priority and severity
Ernst Van Wyk about 2 years ago in Application Server / Alarm App 1 Planned

Native UMAS driver for Modicon PACs

Word is out that active OFS development has stopped. OFS is the current high-performance driver for all Schneider Electric / Modicon PLCs, using its proprietary UMAS protocol. Communication using UMAS and OFS has many advantages over standard Modb...
Guest over 1 year ago in Plant SCADA / Drivers / Protocols 0 Unlikely to implement

Equipment editor use patterns

When creating Equipment types it will save a lot of time when it is possible to use pattern’sFor example when creating an alarm several Item’s need to be created with the same structure: <alarm>_Suppression <alarm>_Condition <alarm&...
Guest over 3 years ago in Plant SCADA / Equipment 3 Future Consideration

Edit Equipment types with a table tool like Excel

when it is needed to update a lot (not all) of variable and trend definitions for example Historian = true within an equipment type. Browsing to the item, opening the definition, add the field and set the value to true will take a lot of time. Whe...
Guest over 3 years ago in Plant SCADA / Equipment 3 Unlikely to implement

Logging Citect alarm in Wonderware Historian

Wondering what the plans are for getting the Citect alarm properties in order when logging into AVEVA History. Today if you log alarms from Citect to the Historian you only get AlarmTag, AlarmName and Category as useful data. All other properti...
Guest over 4 years ago in Plant SCADA / Alarms 0 In Roadmap

Enlarge the tables in the kernel

For instance the CSAToPSI.Subs, it starts with the cluster name, then the tag, which can 79 characters. You can only see 29 characters. Also in a kernel dump the length is limited. Also sorting on different colums would be helpfull.
Guest over 3 years ago in Plant SCADA / Kernel & Diagnostics 0 Reviewed & Categorized