Skip to Main Content
AVEVA™ Products Feedback Portal

Welcome to our new feedback site!


We created this site to hear your enhancement ideas, suggestions and feedback about AVEVA products and services. All of the feedback you share here is monitored and reviewed by the AVEVA product managers.

To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Aspect

Showing 59 of 774

Need a replacement for PrintScreen() function that works in OMI

OMI is missing a way to programmatically print to printer. Like the PrintScreen function in InTouch. Should be able to print the whole application or only part of it, i.e. a popup window.Ref: IMS#2206203
Øyvind Hansen 3 months ago in Application Server / Scripting 1

Provide MyViewApp.Navigation.PreviousVisitedPath

Right now it is possible to create forward and back buttons by using MyViewApp.Navigation.PreSiblingPath and NextSiblingPath respectively. These do not take in consideration last page visited by the user. The workaround is to define a custom names...
Rares Plesea about 1 year ago in Application Server / Development 0

Increase Object Containment Level Limit from 10 to 50+

Increase the Object (and Area) Containment Level Limits from 10 to 50 or more. Today we cannot model more than 10 cascaded containment Objects, and we are forced to treat Areas as Objects to adequately represent electrical hierarchy of our power p...
Keary Dosier 3 months ago in Application Server / Configuration 0

OPC UA Server - Restricting Client Access

Hi, My OEM customer currently uses TOP Server 6 instead of AVEVA OPC UA Server for different reasons. One of them is that it's possible in TOP Server 6 to have different users access different parts of the OPC UA Server via No Access, Read Only or...
Peter Rosenberger 7 months ago in Application Server / Device Integration 1

Symbol Editor: Text Box should scale the same as Text

Text box embedded in a graphic that is embedded and manually scaled (drag corner to change size) does not scale the font. Additional info is in: SR: 960592245 ER: 3912243
Guntars Rubenins 7 months ago in Application Server / Visualization 1

Get Custom Property Reference by script

Allow retrieving a reference from a custom property to reuse it in a graphic. Example: indicate to the user the attribute used in a display and be able to find it in Historian.
Hugues Alexis 9 months ago in Application Server / Scripting 0

can change Height on Combobox

on graphic can change Height on Combobox
Jean-François POULAIN about 1 year ago in Application Server / Visualization 0

Secured and Verify Writes popup for boolean shoud show Onmsg/Offmsg instead of True/False

The popup for secured/verify writes is showing the value True or False. Would be more logical that it uses the OnMsg or OffMsg that is configured for the corresponding attribute.
Lauran Lint 11 months ago in Application Server / Security 0

OS-Configuration Utility needs an option to not overwrite existing Firewall rules during upgrades.

We are using System Platform 2023----After our normal installation and hardening, we have 22 firewall rules on the system. After installing the SP, (with OS-Configuration Utility) we suddenly have 245 rules. See attachment for details. Requirement...
Guest 11 months ago in Application Server / Configuration / Installation / Security 1

Check Computername validity before commencing installation

Check that the computername does not include an "_" or exceed the NetBIOS limit of 15 characters before continuing with installation.
Ernst Van Wyk about 1 year ago in Application Server / Installation 0