To start, select the product of your interest in the left column. Then take a look at the ideas in the list below and VOTE for your favorite ideas submitted by other users. POST your own idea if it hasn’t been suggested yet. Include COMMENTS and share relevant business case details that will help our product team get more information on the suggestion. Please note that your ideas will first be moderated before they are made visible to other users of this portal.

This page is for feedback for specific AVEVA solutions, excluding PI Systems and Data Hub. For links to these other feedback portals, please see the tab RESOURCES below.

ADD A NEW IDEA

Clear

Ideas

Showing 95 of 859

Custom Namespaces values in Object Viewer

Enable the ability to view the runtime values of Custom and Standard Namespaces in the Object Viewer.
Luca Preziosa 9 months ago in Application Server / Diagnostics 1

Validation user access operational permissions to an object prior to writing value to the object attribute

Desired functionality - possibility in run time to get security configuration for logged in user regarding operational permission to specifical security group or validation function that will return information if currently logged in user has ...
Antonina Nilsson 2 months ago in Application Server / Security 0

Industrial Graphic script editor should ask for saving on Exit after ESC key press

When writing some scripts in Industrial Graphic editor, if we press ESC key by mistake, it closes, no matter if there was a script modified or written without asking for saving or not. So instead using Script editor i always write script in Notepa...
Marcin Wozniczka 10 months ago in Application Server / Scripting 2

can change Height on Combobox

on graphic can change Height on Combobox
Jean-François POULAIN over 1 year ago in Application Server / Visualization 0

Compatibility Testing: Aveva software & AI-Based AV — CrowdStrike

Based on the latest trends in cybersecurity and the higher industry requirements, it would be beneficial to have more options for Antivirus (AV) software that could be tested in a controlled environment with AVEVA software. Not having the vendor e...
Guest 5 months ago in Application Server / Security 0 Planned

Symbol Editor: Text Box should scale the same as Text

Text box embedded in a graphic that is embedded and manually scaled (drag corner to change size) does not scale the font. Additional info is in: SR: 960592245 ER: 3912243
Guntars Rubenins 11 months ago in Application Server / Visualization 1

[PlantSCADA] Better support for tag config changes on PlantSCADA end

4.3 Changes to Plant SCADA configuration Where there are changes from the PlantSCADA side, a restart of the connector is required however there are many cases of where the users forget to do this. A reminder message may help. Looks like this is do...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 0 In Roadmap

[PlantSCADA] Fault tolerance to errors on the PlantSCADA side

2.0 Fault Tolerance of the connector to SCADA misconfiguration If there is a misconfiguration on the SCADA side, for example after the system is running, then it can lead to the ctapi connection being dropped and no logs for all tags, and not just...
Marcell Marjee 6 months ago in Historian & Client / Data Acquisition 1 In Roadmap

[PlantSCADA] Make connector activity visible in PlantSCADA UI

The main issue is that if you stop Plant SCADA while a backfilling operation is ongoing but the Connector is still working, then we get the issue that data is written on wrong blocks into historian. To successfully complete the backfill operation,...
Mats-Peter Cansund 6 months ago in Historian & Client / Data Acquisition 3 In Roadmap

Check Computername validity before commencing installation

Check that the computername does not include an "_" or exceed the NetBIOS limit of 15 characters before continuing with installation.
Ernst Van Wyk over 1 year ago in Application Server / Installation 0